The AirTAC GC20006LC2WG AirTAC F.R.L. Combination, G1/8, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, assembled as one coordinated set so the air is cleaned, regulated and lubricated in sequence. This configuration, GC20006LC2WG, is the size 200 unit with a G1/8 (BSPP) port. The filter element is the fine 5 um grade (the W code) rather than the standard 40 um, and the filter bowl drains by differential pressure, so the bowl vents itself as the pressure drop across the element builds. The regulator is the low-pressure type (L code), suited to circuits that run below standard line pressures, and a round pressure gauge with a psi scale is fitted so the setpoint can be read and adjusted directly. Polycarbonate bowls are used at this size, and the mounting bracket is included.
This is a genuine AirTAC part. The GC series is offered in sizes 200, 300, 400 and 600 with matching port sizes, and with options across drain type (differential-pressure, automatic or manual), filter grade (40 um standard or 5 um), gauge style and scale, thread (PT standard, with G and NPT as orderable options) and reverse/check valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.
| Model | GC20006LC2WG AirTAC F.R.L. Combination, G1/8, 5 um |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/8" (G (BSPP) thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/8" · 5 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-06 |
| Build order | Filter → regulator → lubricator |
Feeds the tool-change cylinders, clamps and air-blast nozzles on a machining centre with air that is filtered to 5 um, held at a stable low setpoint and carrying a fine oil mist to keep spindle-adjacent actuators running smoothly.
Supplies the diverters, pushers and gripper cylinders along a packaging conveyor, where the low-pressure regulator holds a gentle, repeatable setpoint for delicate product handling and the lubricator keeps high-cycle cylinders sealed and smooth.
Conditions the air feeding spray guns and air-assisted applicators: the 5 um element removes water and particulates that would ruin a finish, the regulator sets the gun supply pressure, and the lubricator is set to suit the gun manufacturer's requirement.
Start with the port step: size 200 carries the 1/8 in port shown here, and stepping up to 300, 400 or 600 moves you to larger ports and higher flow capacity - match the size to the air demand of the circuit rather than the fitting alone. For the drain, differential-pressure (as fitted here) vents the bowl automatically as the element loads; choose automatic (A) for a fixed timed purge or manual (M) if you want operator-controlled draining. This unit carries the 5 um fine grade (W); the 40 um standard grade suits general line protection, while 5 um is the choice where downstream valves and tools need finer particle removal. The gauge here is the external round type with a psi scale; an embedded square gauge is standard, and MPa or bar scales are available. Thread is G (BSPP) on this code - PT is the standard offering, with G and NPT as orderable options - and the mounting bracket is included. One honest note on sizing: flow is published as curves, not a single rated number, so send us your application details and we will confirm the right size against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.
AirTAC publishes flow for this series as curves rather than a single rated figure, so there is no one l/min or SCFM number we can quote honestly. Send us your application - the air demand of your cylinders or tools and your line pressure - and we will confirm the sizing against the datasheet on request.
The L code means the regulator fitted in this set is the low-pressure variant, intended for circuits that run below standard line pressures. The exact adjustment range for this variant is not published in the material we hold, so confirm the setpoint you need with us and we will verify it against the datasheet. Standard-range GC units are also available if your circuit runs at conventional pressures.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.