The AirTAC GC20006LC2WK AirTAC F.R.L. Combination, PT1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC20006LC2WK is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator set up as one complete air-treatment train. This configuration is the size 200 unit with PT1/8 (1/8 in) ports, the finer 5 um filter element (code W), a differential-pressure drain on the filter bowl, a low-pressure type regulator, a round psi gauge, a reverse/check valve fitted, and a mounting bracket included. The bowls are polycarbonate (PC). Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with a choice of ports, drain types, 40 um or 5 um filter grades, gauge style and scale, thread options and reverse/check valve, so a matching configuration can be specified for other lines. Because flow is published as curves rather than a single rating, we confirm the datasheet figures for your application on request.
| Model | GC20006LC2WK AirTAC F.R.L. Combination, PT1/8 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/8" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/8" · 5 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-06 |
| Build order | Filter → regulator → lubricator |
Feeds the filtered, regulated and lubricated air supply to a small pneumatic press or clamping fixture where the circuit runs at a reduced set pressure and the low-pressure regulator type is the right match.
Conditions the supply to the air cylinders on a packaging or cartoning conveyor, removing water and particulate at 5 um, holding a steady set pressure and carrying oil mist to keep the cylinders running smoothly.
Provides treated air to bench-top test rigs and small lab automation actuators, where the 1/8 in ports, fine 5 um filtration and a psi gauge readout suit compact, instrumented setups.
Start with the size and port: the 200 size with PT1/8 ports suits compact supply points, and larger sizes (300/400/600) step up in port and capacity - match the step to the air demand of the circuit rather than the port alone. Choose the filter grade: 40 um is standard, 5 um (this unit, code W) for finer protection. Choose the drain: differential-pressure (default), automatic or manual. On the regulator, pick standard or low-pressure type, gauge style (embedded square standard, external round optional) and scale (MPa, psi or bar - this unit has a round psi gauge). Select the thread: PT is standard, with G (BSPP) and NPT as order options; add or omit the bracket and reverse/check valve as needed. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Tell us your application and air demand and we will confirm the relevant datasheet flow figures for this configuration on request.
The GC is a three-piece F.R.L. combination - separate filter, regulator and lubricator - so each element can be serviced independently, whereas the GFC two-unit set combines the filter and regulator in one body with a separate lubricator. The W in GC20006LC2WK is the filter grade: 5 um instead of the standard 40 um, for finer protection of downstream components.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.