verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC20006MC2GK AirTAC F.R.L. Combination, G1/8

The AirTAC GC20006MC2GK AirTAC F.R.L. Combination, G1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$70.90 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC20006MC2GK AirTAC F.R.L. Combination, G1/8

The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator assembled as one air-treatment set. This configuration, the GC20006MC2GK, is the 200 size with G1/8 (BSPP) ports and carries a manual-drain filter bowl with the standard 40 um filter element, a standard-type regulator with an included round gauge scaled in psi, a reverse/check valve, and a mounting bracket. The bowls on the 200 size are polycarbonate, so the unit suits general compressed-air duty where the bowls remain visible for level and condensate checks.

This is a genuine AirTAC part. The GC family is available in 200, 300, 400 and 600 sizes with a choice of port, drain type (differential-pressure, automatic or manual), filter grade (40 um standard, 5 um optional), gauge type and scale, thread (PT standard, G and NPT as order options) and bracket configuration. Max inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm the datasheet and sizing figures on request.

GC20006MC2GK AirTAC F.R.L. Combination, G1/8 Technical Specifications

ModelGC20006MC2GK AirTAC F.R.L. Combination, G1/8
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC20006MC2GK AirTAC F.R.L. Combination, G1/8

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 40 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the GC20006MC2GK AirTAC F.R.L. Combination, G1/8 Is Used

precision_manufacturing

Small pneumatic press station

Feeding a compact bench press or clamping cylinder: the filter removes water and particulate from the shop-air drop, the regulator sets the working pressure for the stroke, and the lubricator mists oil to the valve and cylinder seals.

factory

Packaging machine air supply

Point-of-use treatment on a carton sealer or wrapping machine: clean, regulated, lubricated air at the machine inlet protects the directional valves and small actuators that cycle throughout the shift.

settings_input_component

Assembly-bench air drops

Supplying hand tools, air cylinders and fixtures at an assembly workstation: one F.R.L. set conditions the branch line, with the psi gauge giving the operator a local pressure reference and the check valve holding the circuit against backflow.

Is the GC20006MC2GK AirTAC F.R.L. Combination, G1/8 the Right Station?

Start with the port step: the 200 size here is the smallest in the GC range (G1/8 / 1/8 in), and moving up to 300, 400 or 600 gives larger ports and more flow capacity - match the size to the air consumption of the downstream circuit rather than to the port alone. For the drain, manual means someone drains the bowl by hand, while differential-pressure (the default) and automatic drains handle condensate without that routine; choose manual only where a drain check is part of normal maintenance. The 40 um element fitted here is the standard grade; specify code W for the 5 um element if finer filtration is needed. The gauge fitted is a round gauge scaled in psi; embedded square gauges and MPa or bar scales are the other options.

Thread is G (BSPP) on this unit; PT is the catalogue standard and NPT is available as an order option, so confirm the thread your piping needs before ordering. A bracket is included, and the reverse/check valve is fitted. Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

GC20006MC2GK AirTAC F.R.L. Combination, G1/8 FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Tell us your application and air consumption and we will confirm the sizing and the datasheet flow curves for this unit on request.

The M in the code means the filter bowl is drained by hand, which suits installations where a check is already part of the maintenance routine. The GC family is also available with differential-pressure drain (the default) or automatic drain; the regulator adjustment range differs by drain type, with manual-drain units covering 0.05-0.9 MPa (7-130 psi).

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC20006MC2GK AirTAC F.R.L. Combination, G1/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC20006MC2GK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.