The AirTAC GC20006MF2GK AirTAC F.R.L. Combination Unit, G1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The GC20006MF2GK is an AirTAC GC200 three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one prepared-air station. This configuration has a G1/8 (1/8 in) port with G thread, a 40 um filter element in a polycarbonate bowl with a manual drain, and a standard regulator adjustable from 0.05 to 0.9 MPa (7-130 psi). An embedded square gauge with a psi scale is fitted, a reverse/check valve is installed, and a mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GC series is available in 200, 300, 400 and 600 sizes with a port and option step at each size, and choices include drain type, 5 um filtration (code W), gauge scale, thread option and bracket. Flow is published as curves rather than a single rating, so we confirm flow and datasheet figures on request before you order.
| Model | GC20006MF2GK AirTAC F.R.L. Combination Unit, G1/8 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/8" (G (BSPP) thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/8" · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-06 |
| Build order | Filter → regulator → lubricator |
Feeds filtered, regulated and lubricated air to a small CNC machine tool's pneumatic tool-changer and clamping circuits, with the check valve holding downstream pressure if the supply dips.
Prepares air for the divertor and pusher cylinders on a carton packaging conveyor, where the 40 um element protects valve seals and the lubricator keeps cylinder seals running smoothly.
Serves a manual assembly bench with air screwdrivers and small pneumatic clamps, giving the operator a set regulated pressure, oil-mist lubrication and a local psi gauge at the point of use.
Start with the port step: 200 is the smallest GC size at 1/8 in, so step up to 300, 400 or 600 if the line's flow demand points higher - match the size against required flow rather than port size alone. Choose the drain to suit attendance: manual drain (this unit) suits stations visited routinely; automatic or differential-pressure drain suits less accessible installs. Filter grade is 40 um standard, with 5 um (code W) for finer protection. Gauge scale is selectable (MPa, psi or bar), thread is PT as standard with G and NPT as order options, and a bracket is included here. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.
AirTAC publishes flow for the GC series as characteristic curves rather than a single rated figure, so we do not quote a l/min or SCFM number. Send us your application's flow and pressure requirements and we will confirm the sizing from the datasheet on request.
This configuration carries the M code, so the filter bowl is drained by hand - open the drain at the bottom of the bowl to expel collected water. If the installation is hard to reach, the same GC200 combination can be ordered with an automatic drain (code A) or the differential-pressure drain that is the series default.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.