verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC20006MLC2WG AirTAC F.R.L. Combination, G1/8

The AirTAC GC20006MLC2WG AirTAC F.R.L. Combination, G1/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/8" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$59.72 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC20006MLC2WG AirTAC F.R.L. Combination, G1/8

The GC20006MLC2WG is a three-piece AirTAC GC-series F.R.L. combination: a separate filter, regulator and lubricator assembled as one air-preparation unit. This configuration is built in the 200 size with a G1/8 port, carries the W-code 5 um filter element for finer water and particulate removal than the standard 40 um grade, and uses a manual drain on the filter bowl, so an operator opens the drain at service intervals rather than relying on an automatic mechanism. The regulator is the low-pressure type for circuits that run at reduced working pressure, and the C2 code adds an external round gauge with a psi scale for direct set-point reading. The bowl is polycarbonate and a mounting bracket is included.

This is a genuine AirTAC part. The GC family is available in 200, 300, 400 and 600 sizes with stepped ports, a choice of differential-pressure, automatic or manual drains, 40 um or 5 um filtration, standard or low-pressure regulation, and MPa, psi or bar gauge scales. Published flow data appears only as curves rather than a single rating, so ask us to confirm flow and datasheet figures for your application before ordering.

GC20006MLC2WG AirTAC F.R.L. Combination, G1/8 Technical Specifications

ModelGC20006MLC2WG AirTAC F.R.L. Combination, G1/8
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/8" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC20006MLC2WG AirTAC F.R.L. Combination, G1/8

GC200G-series F.R.L. combination, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-06 filter, GR200-06 regulator and GL200-06 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/8" · 5 µm
One size upGC300
Two-unit equivalentGFC200-06
Build orderFilter → regulator → lubricator

Where the GC20006MLC2WG AirTAC F.R.L. Combination, G1/8 Is Used

precision_manufacturing

Benchtop pneumatic press cell

A small workholding press fed from a shop-air drop needs clean, dry, lubricated air held at a reduced working pressure. This unit filters to 5 um, regulates down to the press's set point on the psi gauge, and meters oil mist to the cylinder seals, with the manual drain emptied during shift checks.

conveyor_belt

Food-packaging conveyor diverters

Diverter and gate cylinders on a packaging line run continuously and are sensitive to water and fine grit. This combination conditions the branch line feeding them, and the low-pressure regulator holds the gentler pressure these actuators need, with the round psi gauge letting line staff verify the setting at a glance.

engineering

Laboratory automation fixture

A bench-mounted pick-and-place fixture with small-bore cylinders needs fine filtration and a stable, reduced supply pressure. This unit's 5 um element protects the directional valves, the low-pressure regulator sets the working pressure, and the included bracket mounts the set neatly at the fixture's air inlet.

Is the GC20006MLC2WG AirTAC F.R.L. Combination, G1/8 the Right Station?

Start with the size and port: the 200 size with a 1/8 in port suits the low end of the GC flow range, so match the port step against your line supply and downstream demand, and step up to 300, 400 or 600 if the circuit needs more. Choose the drain to match maintenance practice: manual drain (as here) needs a scheduled operator visit, while automatic and differential-pressure drains handle condensate without one. The 5 um W-grade element is the finer choice where downstream valves and cylinders see finer contamination; 40 um is the standard grade. Gauge scale (MPa, psi or bar) is a readability choice for the maintenance team, and thread is PT as standard with G and NPT available to order.

One honest note on sizing: AirTAC publishes flow for this family as curves, not as a single rated figure, so we cannot quote a number here. Send us your application details and we will confirm sizing against the datasheet curves before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-06 regulator with a GF200-06 filter on that branch.

GC20006MLC2WG AirTAC F.R.L. Combination, G1/8 FAQ

AirTAC publishes flow for the GC family as performance curves rather than a single rated figure, so we do not quote a number here. Tell us your supply pressure and downstream demand and we will confirm the flow from the datasheet curves for this exact model before you order.

The M in the code specifies a manual drain: an operator opens the bowl drain at service intervals to remove collected condensate. If the installation is unattended or drains infrequently, the same GC200 size is also available with an automatic or differential-pressure drain - just ask and we will quote the equivalent code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC20006MLC2WG AirTAC F.R.L. Combination, G1/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC20006MLC2WG and will confirm price, stock and lead time — usually within 7-8 hours.