The AirTAC GC20008C2WG AirTAC F.R.L. Combination, G1/4 Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC20008C2WG is an AirTAC GC200 three-unit F.R.L. combination that conditions compressed air in three stages: a filter removes water and particulate down to 5 um, a standard regulator holds the downstream pressure within its 0.15-0.9 MPa (20-130 psi) adjustment range, and a lubricator meters oil mist into the air line. This configuration is built around a G1/4 port with a differential-pressure drain on the filter bowl, a round gauge reading in psi, and a mounting bracket included for panel or wall fixing. The PC (polycarbonate) bowls suit the -5 to 70 C non-freezing operating range, with a maximum inlet pressure of 1.0 MPa (145 psi).
This is a genuine AirTAC part from the GC series, which spans sizes 200, 300, 400 and 600 with port sizes from 1/4 in upward, plus choices of drain type, filter grade, gauge style and scale, and thread form. Flow is published by AirTAC as curves rather than a single rated figure, so we confirm the datasheet flow numbers for your application on request before you order.
| Model | GC20008C2WG AirTAC F.R.L. Combination, G1/4 Port |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (G (BSPP) thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/4" · 5 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-08 |
| Build order | Filter → regulator → lubricator |
On a machine-tool press line with air-actuated clamps, the GC20008C2WG filters machining moisture and swarf-laden air to 5 um, holds a steady regulated pressure to the clamp cylinders, and carries oil mist to keep the cylinder seals and valve spools lubricated through every cycle.
Feeding the air cylinders and grippers on a carton-forming and sealing machine, this three-unit set cleans the shop air, regulates the pressure that sets gripper force, and lubricates the actuation circuit, with the round psi gauge giving operators a direct reading at the machine.
On a bottling or canning line where air jets divert containers between conveyor lanes, the GC20008C2WG removes water carryover that would spot the containers, regulates the jet pressure for consistent diverting, and oils the divertor cylinders running continuously through the shift.
Start with the size and port step: the GC200 with its 1/4 in port is the entry size of the range, and the 300, 400 and 600 bodies step up in port and flow capacity, so match the frame to the air demand of the circuit rather than oversizing on guesswork. This unit carries the 5 um filter element (the 40 um standard grade is the alternative code) and a differential-pressure drain, which flushes accumulated condensate as the pressure differential rises; automatic or manual drains are available on other codes if you prefer a different drainage habit. The fitted round gauge reads in psi, with MPa and bar scales selectable on other variants. Thread is G here; PT is the standard offering and G and NPT are order options. A mounting bracket is included. Because AirTAC publishes flow only as curves and not as a single rated number, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so there is no one rated flow number we can quote. Tell us your line pressure and the air demand of your circuit and we will confirm the flow from the datasheet curves for this exact unit before you order.
The W in the code GC20008C2WG selects the 5 um element, which strips finer water and particulate than the 40 um standard grade. Choose 5 um where downstream valves, cylinders or air tools need cleaner air; the 40 um grade is the default on other GC codes and suits general-purpose supply where finer filtration is not required.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.