The AirTAC GC20008MC2W AirTAC F.R.L. Combination, 1/4 in, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GC20008MC2W is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one air-preparation set. This configuration is built for a 1/4 in PT port, with a manual-drain filter bowl, a fine 5 um filter element, a standard regulator fitted with an external round gauge scaled in psi, and a mounting bracket included. The polycarbonate bowls let you see condensate and oil level at a glance, and the lubricator meters oil mist into the air line to protect downstream pneumatic components.
This is a genuine AirTAC part from the GC series, which spans sizes 200 to 600 with port options from 1/8 in to 1 in and thread choices of PT, G or NPT. Drain, filter grade, gauge style and scale are all selectable across the range. Flow figures for this series are published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GC20008MC2W AirTAC F.R.L. Combination, 1/4 in, 5 um |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/4" · 5 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-08 |
| Build order | Filter → regulator → lubricator |
A bench-mounted F.R.L. set ahead of air cylinders on a small press or clamping fixture: the regulator holds a steady set pressure, the 5 um element keeps solenoid valves clean, and the lubricator mists oil to the cylinders.
Feeding clean, regulated, lubricated air to the diverters, grippers and seal jaws of a packaging line, where the 1/4 in port suits compact machine manifolds and the manual drain suits a daily start-up check routine.
Installed at a point-of-use drop from a plant air ring main, giving an individual cell or workbench its own filtration, pressure setting and lubrication instead of relying on a shared header.
Start with the port and size step: the GC200 size shown here carries a 1/4 in port, and larger sizes (300, 400, 600) step up in port and flow capacity - match the size to the air demand of the machine rather than the pipe alone. Drain type is a real choice: manual drain means someone vents the bowl, while automatic and differential-pressure drains are available if the installation is not checked daily. Filter grade is selectable too - 40 um is the standard element and this unit carries the finer 5 um element (code W) for more sensitive downstream equipment. Gauge style and scale (round or square; MPa, psi or bar) and thread (PT standard, G or NPT to order) are also decodable choices.
Because flow for this series is published as curves and not as a single rated figure, send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Send us your application's air demand and we will confirm the datasheet flow figures for this 1/4 in, size 200 combination on request before you order.
The M in the code GC20008MC2W selects a manual-drain filter bowl: condensate collects in the polycarbonate bowl and is vented by hand. If the installation is not visited daily, the same series can be ordered with an automatic drain (code A) or a differential-pressure drain (blank) instead - the regulation range differs by drain type, with manual-drain versions adjustable from 0.05-0.9 MPa (7-130 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.