The AirTAC GC20008MC2WGK AirTAC F.R.L. Combination, G1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).
The GC20008MC2WGK is an AirTAC GC200 three-unit F.R.L. combination: a separate filter, regulator and lubricator assembled as one set to clean, regulate and oil-mist lubricate compressed air. This configuration is built on the 200 size with G1/4 (BSPP) ports, a manual drain on the filter bowl, a 5 um filter element (the finer optional grade; 40 um is the standard), a round psi gauge on the regulator, a reverse/check valve, and a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. The filter bowl is PC (polycarbonate) at this size; only the 600 size uses aluminium alloy.
This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with port sizes stepping up from 1/8 in to 1 in, and with choices of drain type, filter grade, gauge style and scale, thread (PT standard, G and NPT as order options) and reverse/check valve. Flow is published as curves rather than a single rating, so ask us to confirm sizing and datasheet figures against your application before ordering.
| Model | GC20008MC2WGK AirTAC F.R.L. Combination, G1/4 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (G (BSPP) thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/4" · 5 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-08 |
| Build order | Filter → regulator → lubricator |
Booth air going to spray guns needs water and particles removed, pressure held steady at the gun, and a light oil mist to keep air motors and triggers running smoothly - exactly the three jobs this filter, regulator and lubricator set splits across its three units.
A workholding or small press circuit fed at 1/4 in benefits from clean, moisture-reduced air at a set regulator pressure, with lubrication carried to the cylinder seals over long production runs.
Stopper cylinders, pushers and diverters on a packaging line run constantly; a three-unit F.R.L. at the line drop keeps grit and water out, holds the pressure the actuators were set up with, and mists oil to extend seal life.
Step through the real choices in this order. First, size and port: 200 with 1/4 in ports suits lighter duty lines; step up to 300, 400 or 600 when the circuit demands larger ports and more flow, and match the port code (06 through 25) to your piping. Second, drain type: this code carries a manual drain, which you open periodically to dump collected water; automatic and differential-pressure drains are available on other codes if you cannot rely on manual attention. Third, filter grade: 40 um is the standard element and W selects this 5 um element for finer protection downstream. Fourth, gauge: this unit carries a round gauge with a psi scale; embedded square gauges and MPa or bar scales are the other catalogue options. Fifth, thread: PT is the standard thread; G (BSPP), as on this code, and NPT are ordered options. A mounting bracket is included, and the reverse/check valve is fitted. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a rated flow, Cv or SCFM figure. Tell us your application and line pressure and we will confirm the sizing from the datasheet curves on request before you order.
The M in the code selects a manual drain on the filter bowl: you open it periodically to discharge collected water, which suits attended installations or points already on a maintenance round. If the unit sits unattended or upstream of sensitive equipment, the automatic (A) or differential-pressure (blank) drain options on other GC codes remove that manual step.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.