verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC20008MF2K AirTAC F.R.L. Combination PT1/4 Manual Drain

The AirTAC GC20008MF2K AirTAC F.R.L. Combination PT1/4 Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$71.46 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC20008MF2K AirTAC F.R.L. Combination PT1/4 Manual Drain

The GC20008MF2K is an AirTAC GC200 three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one air-preparation set. This configuration is built around a 1/4 in PT port, a 40 um filter element and a manual drain, so the operator drains the filter bowl by hand as part of routine checks. The regulator carries a standard adjustment range of 0.05-0.9 MPa (7-130 psi) and is fitted with an embedded square gauge scaled in psi, with an external round gauge available as an option. A reverse/check valve is fitted, and the polycarbonate bowl suits the compressed-air duty of this size.

This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600, with port sizes stepping up from 1/4 in through 1 in, drain choices of differential-pressure, automatic or manual, a 40 um standard element or a 5 um (W) element, and gauge scales in MPa, psi or bar. Flow figures for this series are published as curves rather than a single rating, so we confirm the datasheet and sizing on request before you order.

GC20008MF2K AirTAC F.R.L. Combination PT1/4 Manual Drain Technical Specifications

ModelGC20008MF2K AirTAC F.R.L. Combination PT1/4 Manual Drain
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (PT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC20008MF2K AirTAC F.R.L. Combination PT1/4 Manual Drain

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 40 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the GC20008MF2K AirTAC F.R.L. Combination PT1/4 Manual Drain Is Used

precision_manufacturing

CNC machine air supply

Feeding filtered, regulated and lubricated air to the pneumatic clamps and tool-change cylinders on a CNC machining centre, with the psi gauge letting setters verify set pressure at the machine.

conveyor_belt

Packaging line actuators

Conditioning the air supply to diverters, pushers and seal jaws on a packaging conveyor, where the lubricator keeps cylinder seals working and the manual drain is emptied during line cleaning.

science

Lab automation benches

Preparing compressed air for bench-top laboratory automation - grippers, valves and small actuators - with the 40 um element and check valve protecting the downstream circuit.

Is the GC20008MF2K AirTAC F.R.L. Combination PT1/4 Manual Drain the Right Station?

Start with the port and size step: this unit is the 200 size at 1/4 in PT, and larger GC sizes (300/400/600) move up to 1/2 in, 3/4 in and 1 in ports for higher air demand. Choose the drain to match maintenance habits: manual (as here) means an operator drains the bowl, automatic handles it unattended, and differential-pressure is the default. Pick the filter grade for the air quality the downstream tools need: 40 um standard for general plant air, 5 um (code W) where finer particulate removal matters. Set the gauge scale to suit the team - MPa, psi or bar - and note the thread: PT is the standard here, with G (BSPP) and NPT available as order options. A mounting bracket is included.

Because the catalogue publishes flow as curves rather than one rated number, ask us to confirm the flow and datasheet figures against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

GC20008MF2K AirTAC F.R.L. Combination PT1/4 Manual Drain FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Send us your application details and we will confirm the flow and datasheet figures for this 1/4 in, size-200 unit on request before you order.

The M in the code GC20008MF2K specifies a manual drain: the filter bowl is drained by hand as part of routine maintenance. If you would rather not rely on an operator, the same GC200 combination is available with an automatic drain (code A) or the differential-pressure drain that is the default, and the filter element can be specified as 5 um (code W) instead of the standard 40 um.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC20008MF2K AirTAC F.R.L. Combination PT1/4 Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC20008MF2K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.