AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC20008MLF2G AirTAC F.R.L. Combination, G1/4, Manual Drain

The AirTAC GC20008MLF2G AirTAC F.R.L. Combination, G1/4, Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$59.76 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC20008MLF2G AirTAC F.R.L. Combination, G1/4, Manual Drain

The AirTAC GC20008MLF2G is a three-piece F.R.L. combination unit that conditions compressed air in one assembly: a filter removes water and particulate down to 40 um, a low-pressure regulator sets downstream pressure, and a lubricator adds oil mist for downstream air tools and cylinders. This unit is built in the GC200 size with a G1/4 (1/4 in) port and G thread. The filter bowl is polycarbonate (PC) with a manual drain, so condensate is emptied by hand - a good fit where automatic draining is not wanted. The regulator is the low-pressure type and is fitted with an embedded square gauge scaled in psi; an external round gauge is optional. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with matching port sizes, and options include drain type, 5 um filtration (code W), gauge scale, thread (PT standard; G and NPT are order options) and a reverse/check valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and flow figures for your application on request.

GC20008MLF2G AirTAC F.R.L. Combination, G1/4, Manual Drain Technical Specifications

ModelGC20008MLF2G AirTAC F.R.L. Combination, G1/4, Manual Drain
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC20008MLF2G AirTAC F.R.L. Combination, G1/4, Manual Drain

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 40 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the GC20008MLF2G AirTAC F.R.L. Combination, G1/4, Manual Drain Is Used

factory

Packaging machine air supply

Feeds filtered, regulated and lubricated air to the cylinders and actuators on a carton-forming or wrapping line, with the manual drain emptied during scheduled changeover.

precision_manufacturing

Pneumatic press station

Conditions the air feeding a small bench pneumatic press or clamping fixture, where the low-pressure regulator suits circuits that run at reduced setpoints and the psi gauge gives a clear local readout.

conveyor_belt

Conveyor diverters and stops

Supplies the air cylinders that raise diverters, gates and stoppers on a conveyor line, keeping water and 40 um-scale particulate out of the valves while oil mist lubricates the cylinders.

Is the GC20008MLF2G AirTAC F.R.L. Combination, G1/4, Manual Drain the Right Station?

Start with size and port: the GC200 carries a 1/4 in port, and stepping up to GC300, GC400 or GC600 gives larger ports and more flow - size against the air demand of the machine, not just the pipe thread. Drain choice matters: this unit has a manual drain, so plan a routine drain check; automatic and differential-pressure drains are available elsewhere in the series. Filtration is 40 um standard; choose the W code for 5 um where finer protection is needed. The gauge here is the embedded square type scaled in psi; MPa or bar scales and an external round gauge can be specified. Thread is G (BSPP) on this unit; PT is the standard series thread and NPT is also an order option. A mounting bracket is included, and the regulator is the low-pressure type - its exact adjustment range is not published in the catalogue, so confirm it with us before ordering. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

GC20008MLF2G AirTAC F.R.L. Combination, G1/4, Manual Drain FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Tell us your application and required air demand and we will confirm the flow figures from the datasheet on request.

The M in the model code specifies a manual drain on the filter bowl: condensate is emptied by hand, which suits installations already covered by a maintenance routine. If you prefer the bowl to discharge without operator action, the GC series is also available with automatic or differential-pressure drains - ask us for the equivalent model code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC20008MLF2G AirTAC F.R.L. Combination, G1/4, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC20008MLF2G and will confirm price, stock and lead time — usually within 7-8 hours.