verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

GC20008MLF2GK AirTAC F.R.L. Unit G1/4, Manual Drain, Psi

The AirTAC GC20008MLF2GK AirTAC F.R.L. Unit G1/4, Manual Drain, Psi is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$71.11 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC20008MLF2GK AirTAC F.R.L. Unit G1/4, Manual Drain, Psi

The GC20008MLF2GK is an AirTAC GC-series three-unit F.R.L. combination: a separate filter, regulator and lubricator assembled as one air-preparation set. It cleans compressed air by removing water and particulate down to the standard 40 um grade, regulates downstream pressure with the low-pressure type regulator, and adds oil-mist lubrication for downstream air tools and cylinders. This configuration is built for a G1/4 (1/4 in) port with G thread, carries a manual drain on the filter bowl, a fitted square gauge reading in psi, a reverse/check valve, and includes a mounting bracket.

This is a genuine AirTAC part from the GC200 size class, one of four sizes (200/300/400/600) that step up in port size and flow capacity. Across the range you can order different drain types, a 5 um filter grade (code W), alternative gauge scales (MPa/psi/bar), and PT or NPT thread in place of G. Flow is published as curves rather than a single rated figure, so we confirm the datasheet and sizing figures on request.

GC20008MLF2GK AirTAC F.R.L. Unit G1/4, Manual Drain, Psi Technical Specifications

ModelGC20008MLF2GK AirTAC F.R.L. Unit G1/4, Manual Drain, Psi
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC20008MLF2GK AirTAC F.R.L. Unit G1/4, Manual Drain, Psi

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 40 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the GC20008MLF2GK AirTAC F.R.L. Unit G1/4, Manual Drain, Psi Is Used

settings_input_component

Pneumatic panel build for packaging machinery

Mounted on the bracket inside a machine's air-preparation panel, this three-unit set filters, regulates and lubricates the supply feeding the packaging machine's cylinders and valves, with the psi gauge giving operators a direct reading at the panel.

conveyor_belt

Conveyor drive and stopper circuits

Installed at the drop point feeding a conveyor line's air-operated stoppers and pushers, the set removes condensed water and 40 um particulate, holds the low regulated pressure the stopper cylinders need, and mists oil to keep their seals and surfaces lubricated.

build

Workshop air drops for assembly tooling

Fitted at a bench drop serving air screwdrivers, ratchets and impact tools, the combination protects the tools from water and debris, sets the working pressure on the psi gauge, and delivers oil mist that extends tool life between services.

Is the GC20008MLF2GK AirTAC F.R.L. Unit G1/4, Manual Drain, Psi the Right Station?

Choose the GC200 size with the 1/4 in port when your line runs at modest flow; step up to GC300/400/600 if the circuit demands more. The manual drain on this unit means an operator or maintenance routine opens the bowl drain to discharge collected water - pick the automatic or differential-pressure drain code instead if you want unattended draining. The standard 40 um grade suits general-purpose protection; specify the W code for the 5 um grade where finer filtration is needed. The fitted square gauge reads in psi; MPa or bar scales and an external round gauge are order options. Thread here is G (BSPP); PT is the standard thread and NPT is available to order. The low-pressure type regulator is intended for circuits that work below standard regulation ranges - the exact range for the low-pressure type is not published, so confirm it with us. Note that flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

GC20008MLF2GK AirTAC F.R.L. Unit G1/4, Manual Drain, Psi FAQ

AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote a rated flow number. Send us your line pressure and the flow your circuit needs, and we will confirm the sizing against the datasheet curves on request before you order.

The M in the code sets a manual drain: collected water is discharged by opening the bowl drain during maintenance rounds, which suits attended installations; automatic and differential-pressure drain codes are available if you prefer unattended draining. The K code fits a reverse/check valve that holds downstream pressure if the supply is interrupted. Both are decodable order options, and the low-pressure regulator range for this type should be confirmed with us as it is not published.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC20008MLF2GK AirTAC F.R.L. Unit G1/4, Manual Drain, Psi

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC20008MLF2GK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.