The AirTAC GC20008MLF2WK AirTAC F.R.L. Combination, PT1/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$71.63 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC20008MLF2WK AirTAC F.R.L. Combination, PT1/4

The GC20008MLF2WK is an AirTAC GC-series three-unit F.R.L. combination: a separate filter, pressure regulator and lubricator assembled as one air-preparation set for compressed air. This configuration is built around a PT1/4 (1/4 in) port with standard PT thread, a 5 um filter element (the finer of the two published grades, 40 um being standard), a manual drain on the filter bowl, and a low-pressure type regulator. The square gauge fitted to this unit reads in psi, and a reverse/check valve is fitted to hold downstream pressure if the upstream supply is interrupted. The polycarbonate bowls are suited to the published -5 to 70 C (non-freezing) operating range, with a maximum inlet pressure of 1.0 MPa (145 psi).

This is a genuine AirTAC part. The GC200 size is the compact step in the GC range, which spans sizes 200, 300, 400 and 600 with a choice of ports, threads (PT standard, G and NPT as order options), drain types, filter grades, gauge scales and bracket options. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application on request.

GC20008MLF2WK AirTAC F.R.L. Combination, PT1/4 Technical Specifications

ModelGC20008MLF2WK AirTAC F.R.L. Combination, PT1/4
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC20008MLF2WK AirTAC F.R.L. Combination, PT1/4

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 5 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the GC20008MLF2WK AirTAC F.R.L. Combination, PT1/4 Is Used

precision_manufacturing

Pneumatic clamping on assembly fixtures

A bench-mounted clamping fixture fed at a low set pressure: the GC20008MLF2WK filters the shop air to 5 um, regulates it with the low-pressure type regulator, oils the downstream cylinders via the lubricator, and the check valve holds the clamp if supply air drops.

build

Paint-spray gun supply at a finishing bench

A spray booth take-off point where clean, regulated, lubricated air matters: the 5 um element removes water and particulate before the gun, the manual drain is bled at shift start, and the psi square gauge gives the operator a direct setpoint readout.

conveyor_belt

Air cylinders on packaging conveyor lines

A packaging line running small actuated cylinders and air jets from a 1/4 in drop: this three-unit set conditions the air at the drop point, the low-pressure regulator suits gentle actuation, and the included bracket mounts the set beside the machine frame.

Is the GC20008MLF2WK AirTAC F.R.L. Combination, PT1/4 the Right Station?

Choose the GC200 size and its PT1/4 port to match your line's connection and expected air demand - larger sizes carry larger ports and more flow, and the published flow curves (not a single rating) are the honest way to size the unit, so let us confirm the fit against your application before ordering. This configuration already fixes several real choices: the 5 um element (W) for finer water-and-particulate removal than the 40 um standard, a manual drain you operate by hand rather than an automatic or differential-pressure drain, and a low-pressure type regulator whose exact adjustment range is not published - confirm it with us if your setpoint matters. The square gauge reads in psi; external round gauges and MPa or bar scales are the other published options. PT is the standard thread on this unit, with G (BSPP) and NPT available as order options, and a mounting bracket is included.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

GC20008MLF2WK AirTAC F.R.L. Combination, PT1/4 FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a rated flow, Cv or SCFM figure. Tell us your application and we will confirm the sizing against the datasheet curves on request before you order.

The M in the code specifies a manual drain on the filter bowl: you open it by hand to purge collected water, instead of the automatic or differential-pressure drain options. The L specifies the low-pressure type regulator; its exact adjustment range is not published, so confirm it with us if your setpoint is critical.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC20008MLF2WK AirTAC F.R.L. Combination, PT1/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC20008MLF2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.