verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC300-08 AirTAC F.R.L. Combination G1/4 Low-Pressure 5 um

The AirTAC GC300-08 AirTAC F.R.L. Combination G1/4 Low-Pressure 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$87.06 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC300-08 AirTAC F.R.L. Combination G1/4 Low-Pressure 5 um

The AirTAC GC300 series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator assembled as one air-treatment stack. This GC300-08 configuration is built for a 1/4 in port (G thread; PT is the standard form and G/NPT are orderable thread options), with the fine 5 um filter element (code W), a manual drain on the filter bowl, the low-pressure type regulator, and a round external gauge reading in psi. The polycarbonate bowls suit the -5 to 70 C (non-freezing) operating range, and maximum working (inlet) pressure is 1.0 MPa (145 psi).

This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600, with choices of port size, drain type, filter grade (40 um standard, 5 um optional), gauge style and scale, and thread form. Flow is published in the catalogue as curves rather than a single rated figure, so we confirm the datasheet and flow figures for your application on request.

GC300-08 AirTAC F.R.L. Combination G1/4 Low-Pressure 5 um Technical Specifications

ModelGC300-08 AirTAC F.R.L. Combination G1/4 Low-Pressure 5 um
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC300-08 AirTAC F.R.L. Combination G1/4 Low-Pressure 5 um

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the GC300-08 AirTAC F.R.L. Combination G1/4 Low-Pressure 5 um Is Used

factory

Paint and coating spray lines

Feeds spray guns and atomising stations on a finishing line, where the 5 um element protects the gun from water and particulate and the lubricator mists oil into the air stream for smooth trigger and needle valve operation.

conveyor_belt

Packaging machinery air supply

Conditions the air feeding carton sealers, case packers and bagging machines, giving the cylinders and actuators on the conveyor line filtered, regulated and lubricated air at a set pressure.

precision_manufacturing

Pneumatic press and clamping fixtures

Supplies workholding clamps and small pneumatic presses on a machining cell, where the regulator holds a steady clamping pressure, the 5 um grade keeps valve spools clean and the lubricator reduces seal and bore wear.

Is the GC300-08 AirTAC F.R.L. Combination G1/4 Low-Pressure 5 um the Right Station?

Start from the flow your line needs and step up through the sizes (200, 300, 400, 600), each with its matching port - here 300 with a 1/4 in port. Because published flow is a curve, not one rated number, ask us to check the curve against your application before ordering. This unit carries the 5 um element; the 40 um standard grade is available if finer filtration is not required. The manual drain means an operator opens the bowl drain periodically - if you prefer automatic or differential-pressure draining, those variants exist in the family. The low-pressure regulator type is chosen where the working band sits below the standard range; the exact adjustment range for the low-pressure type is not published in the sheet we work from, so we confirm it on request. The round psi gauge is fitted here; embedded square gauges and MPa/bar scales are the other options. Thread is G in this code, with PT (standard) and NPT as orderable alternatives, and the mounting bracket is included.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

GC300-08 AirTAC F.R.L. Combination G1/4 Low-Pressure 5 um FAQ

AirTAC publishes flow for this series as curves, not as a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Tell us your application and we will confirm the flow figures from the datasheet on request before you order.

The M in the code GC30008MLC2WG specifies a manual drain on the filter bowl: condensate is emptied by opening the drain by hand as part of routine checks. The GC family also offers automatic and differential-pressure drain variants, so if you would rather not rely on manual draining, we can quote the matching code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC300-08 AirTAC F.R.L. Combination G1/4 Low-Pressure 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30008MLC2WG and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.