The AirTAC GC30008C2GK AirTAC F.R.L. Combination, G1/4 Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$98.12 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30008C2GK AirTAC F.R.L. Combination, G1/4 Port

The GC30008C2GK is a genuine AirTAC three-unit F.R.L. combination in the GC300 series: a separate air filter, pressure regulator and oil-mist lubricator assembled as one 3-piece set. This configuration is sized for a 1/4 inch port with G (BSPP) thread. The filter stage removes water and particulate down to the standard 40 um grade, with a differential-pressure drain that bleeds accumulated condensate automatically as pressure differential builds. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi), and a round external gauge with a psi scale is fitted so downstream pressure can be read directly. The lubricator meters oil mist into the air line for downstream pneumatic components, and a reverse/check valve is fitted to hold downstream settings if upstream supply is interrupted.

This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600 with a choice of ports and threads, filter grade (40 um standard, 5 um with code W), drain type (differential-pressure, automatic or manual), gauge scale (MPa, psi or bar) and the reverse/check valve option. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rated figure, so we confirm flow and datasheet figures on request.

GC30008C2GK AirTAC F.R.L. Combination, G1/4 Port Technical Specifications

ModelGC30008C2GK AirTAC F.R.L. Combination, G1/4 Port
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30008C2GK AirTAC F.R.L. Combination, G1/4 Port

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the GC30008C2GK AirTAC F.R.L. Combination, G1/4 Port Is Used

precision_manufacturing

CNC machine tool air supply

Feeding filtered, regulated and lubricated air to the pneumatic actuators, tool-clamp cylinders and chip-clearing jets on a machining centre, with the psi gauge giving the setter a direct readout at the machine.

conveyor_belt

Packaging line cylinder supply

Conditioning the air feeding pick-and-place and carton-closing cylinders on a packaging conveyor, where the lubricator keeps seal life up and the check valve holds the set pressure through brief supply dips.

factory

Assembly station drop legs

A point-of-use F.R.L. set at an assembly bench drop, removing water and scale from the shop air line, holding a stable working pressure for air tools and screwdrivers, and oil-misting the tool circuit.

Is the GC30008C2GK AirTAC F.R.L. Combination, G1/4 Port the Right Station?

Start with the port step: size 300 carries a 1/4 inch port, and the GC family steps through 200, 300, 400 and 600 as port size and flow capacity rise - match the size to the air consumption of the downstream circuit. Choose the drain type where it applies: this unit uses the differential-pressure drain (default); automatic (code A) or manual (code M) drains are available in the family. Filter grade is 40 um standard; specify 5 um (code W) where finer particulate removal is needed. Gauge scale is selectable (MPa, psi or bar) - this configuration carries a round psi gauge. Thread is G (BSPP) here; PT is the standard thread and G/NPT are order options. A mounting bracket is included. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

GC30008C2GK AirTAC F.R.L. Combination, G1/4 Port FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number. Tell us your working pressure and air consumption and we will confirm the correct size from the datasheet curves on request before you order.

The C2 suffix in GC30008C2GK specifies a round external gauge with a psi scale; the embedded square gauge with MPa/psi/bar scales is the family standard and the round gauge is the optional style. The K suffix specifies a reverse/check valve fitted, which holds the downstream setting if the upstream supply drops.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30008C2GK AirTAC F.R.L. Combination, G1/4 Port

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30008C2GK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.