verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30008G AirTAC F.R.L. Combination, G1/4, 5 um, Manual Drain

The AirTAC GC30008G AirTAC F.R.L. Combination, G1/4, 5 um, Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$86.91 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30008G AirTAC F.R.L. Combination, G1/4, 5 um, Manual Drain

The GC30008G is a three-piece AirTAC GC series F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one air-preparation set. This configuration is built for G1/4 (1/4 in) ports with G thread, carries a 5 um filter element for finer particulate and water removal than the standard 40 um grade, and uses a manual drain on the filter bowl, so an operator drains collected condensate by hand as part of routine checks. The regulator is the standard type with an adjustment range of 0.05-0.9 MPa (7-130 psi), and this unit is fitted with an external round gauge scaled in psi; the embedded square gauge is the standard option and MPa or bar scales can be ordered. The polycarbonate bowl suits the 300 size, maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C in non-freezing conditions.

This is a genuine AirTAC part. The GC series is available in 200, 300, 400 and 600 sizes covering ports from 1/8 in to 1 in, with choices of drain type, filter grade, gauge style and scale, thread (PT standard, G and NPT as order options) and a mounting bracket. Flow is published in the catalogue as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application on request.

GC30008G AirTAC F.R.L. Combination, G1/4, 5 um, Manual Drain Technical Specifications

ModelGC30008G AirTAC F.R.L. Combination, G1/4, 5 um, Manual Drain
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30008G AirTAC F.R.L. Combination, G1/4, 5 um, Manual Drain

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the GC30008G AirTAC F.R.L. Combination, G1/4, 5 um, Manual Drain Is Used

precision_manufacturing

CNC machine tool air supply

A filtered, regulated and lubricated air drop feeding the tool-changer and clamping cylinders on a machining centre, where the 5 um element protects fine spool valves and the lubricator keeps actuation air oil-misted.

conveyor_belt

Packaging line cylinder circuits

Air preparation for the pick-and-place and sealing cylinders on a packaging conveyor, with the regulator holding a steady set pressure for consistent cycle behaviour and the manual-drain filter emptied during shift checks.

factory

Assembly station FRL drop

A bench-side air set for manual assembly stations running air tools and small actuators, giving one point where the operator reads line pressure on the psi gauge, drains the bowl and maintains the oil-mist feed.

Is the GC30008G AirTAC F.R.L. Combination, G1/4, 5 um, Manual Drain the Right Station?

Start with the size and port: the 300 size with G1/4 ports is the right step when your line runs on 1/4 in piping and your air demand sits in that size band - step up to 400 or 600 for larger flows, down to 200 for compact circuits. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering. Then set the options this code carries: manual drain (operator-drained bowl, simplest and lowest cost, versus automatic or differential-pressure drain for unattended operation), the 5 um W-grade element where downstream valves and cylinders need finer filtration than the standard 40 um, and the round external gauge with psi scale (square embedded gauge is standard; MPa and bar scales are available). G thread is an order option alongside the PT standard and NPT, and the mounting bracket is included. Confirm the exact thread and gauge scale you want when ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

GC30008G AirTAC F.R.L. Combination, G1/4, 5 um, Manual Drain FAQ

AirTAC publishes flow for the GC series as curves in the catalogue, not as a single rated number, so we do not quote a figure that is not in the datasheet. Tell us your line pressure, port size and expected air consumption, and we will confirm the flow curve and correct sizing from the datasheet on request before you order.

The M in the code sets a manual drain on the filter bowl: an operator opens the drain to release collected water and contaminants, typically as part of a scheduled check. If you cannot guarantee that routine, the GC series also offers automatic and differential-pressure drain options on the same sizes - ask us to quote the alternative code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30008G AirTAC F.R.L. Combination, G1/4, 5 um, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30008MC2WG and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.