verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30008LF2K AirTAC F.R.L. Combination, PT1/4, Low-Pressure

The AirTAC GC30008LF2K AirTAC F.R.L. Combination, PT1/4, Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$98.78 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30008LF2K AirTAC F.R.L. Combination, PT1/4, Low-Pressure

The AirTAC GC30008LF2K is a three-piece F.R.L. combination that filters, regulates and lubricates compressed air from a single assembled set: a separate filter, a pressure regulator and an oil-mist lubricator. This 300-size unit is built with a PT1/4 (1/4 in) PT thread, the standard 40 um filter element for general-purpose water and particulate removal, and a differential-pressure drain on the filter bowl. It is a low-pressure type, and the fitted reverse/check valve holds downstream pressure if the upstream supply is interrupted. The embedded square gauge reads in psi, so the set pressure can be checked at a glance.

This is a genuine AirTAC part in the GC series, which spans sizes 200, 300, 400 and 600 with port options from 1/8 in to 1 in and G (BSPP) or NPT threads as order options alongside the PT standard. Maximum inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing). Flow figures for this series are published as curves rather than a single rated number, so ask us to confirm the datasheet and sizing for your application.

GC30008LF2K AirTAC F.R.L. Combination, PT1/4, Low-Pressure Technical Specifications

ModelGC30008LF2K AirTAC F.R.L. Combination, PT1/4, Low-Pressure
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30008LF2K AirTAC F.R.L. Combination, PT1/4, Low-Pressure

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the GC30008LF2K AirTAC F.R.L. Combination, PT1/4, Low-Pressure Is Used

factory

Paint spray booth supply line

Feeds spray guns on a finishing line with cleaned, pressure-stabilised and oil-misted air, so the gun atomisation stays consistent through a shift while the check valve holds the set pressure if the plant supply dips.

precision_manufacturing

Pneumatic press on an assembly line

Supplies a small pneumatic press or clamping fixture where the regulator sets the working pressure for consistent forming force, the lubricator mists the cylinder seals, and the 40 um element keeps machining swarf and condensate out of the valve stack.

conveyor_belt

Packaging machine air supply

Conditions the air feeding carton-sealing and wrapping machinery, where the low-pressure regulator suits equipment that runs at reduced supply pressure and the differential-pressure drain clears accumulated water during continuous production runs.

Is the GC30008LF2K AirTAC F.R.L. Combination, PT1/4, Low-Pressure the Right Station?

Start with the port step: this unit is 300 size with a PT1/4 (1/4 in) PT thread, so match it to the line size and the air demand of the equipment it feeds - larger sizes (400, 600) carry bigger ports for higher demand, and G (BSPP) or NPT threads can be ordered instead of PT. The 40 um element is the standard grade for general plant air; if finer filtration is needed, the W-coded 5 um grade is available in the series. Drain choice matters: this unit uses the differential-pressure drain (the default), while automatic (A) and manual (M) drains are decodable options. The gauge here is the embedded square type reading psi; MPa or bar scales and an external round gauge are alternatives, and the fitted K-coded check valve is what sets this configuration apart from standard sets.

Because flow for the GC series is published only as curves and not as a single rated figure, and the exact regulation range of the low-pressure type is not published, ask us to confirm sizing and the regulator range against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

GC30008LF2K AirTAC F.R.L. Combination, PT1/4, Low-Pressure FAQ

AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so there is no one rated flow number we can quote. Tell us your application and operating pressure and we will confirm the sizing from the datasheet on request before you order.

The L in the code marks this as a low-pressure regulator type rather than the standard version; the exact regulation range for the low-pressure type is not published, so we confirm it on request. The trailing K means a reverse/check valve is fitted, which holds downstream pressure if the upstream supply is cut. The F2 code is the embedded square gauge reading in psi.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30008LF2K AirTAC F.R.L. Combination, PT1/4, Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30008LF2K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.