AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30008MLC2 AirTAC F.R.L. Combination, PT1/4, Low-Pressure

The AirTAC GC30008MLC2 AirTAC F.R.L. Combination, PT1/4, Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$87.55 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30008MLC2 AirTAC F.R.L. Combination, PT1/4, Low-Pressure

The GC30008MLC2 is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one prepared air-treatment set. This configuration is the 300 size with a PT1/4 (1/4 in) port, PT thread, a 40 um standard filter element and a manual-drain filter bowl in polycarbonate. The regulator is the low-pressure type, so it is intended for circuits that run below standard regulated pressures; the exact adjustment range is not published, so confirm it against your set pressure before ordering. A round external gauge on the psi scale is fitted, and the mounting bracket is included.

This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600 with matching port sizes, and with choices of thread (PT standard, G or NPT to order), drain type (differential-pressure, automatic or manual), filter grade (40 um standard, 5 um with code W), gauge style and scale, and low-pressure or standard regulator type. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet and sizing for your application on request.

GC30008MLC2 AirTAC F.R.L. Combination, PT1/4, Low-Pressure Technical Specifications

ModelGC30008MLC2 AirTAC F.R.L. Combination, PT1/4, Low-Pressure
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (PT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30008MLC2 AirTAC F.R.L. Combination, PT1/4, Low-Pressure

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the GC30008MLC2 AirTAC F.R.L. Combination, PT1/4, Low-Pressure Is Used

precision_manufacturing

CNC machine pneumatic clamping

Feeds filtered, regulated and lubricated air to workholding clamps and swing cylinders on a machining cell, with the low-pressure regulator suited to circuits running below standard line pressure.

conveyor_belt

Packaging line air cylinders

Prepares the air supply for diverters, pushers and sealing cylinders on a packaging conveyor, where the lubricator keeps cylinder seals moving smoothly through long production shifts.

factory

Plant air drops for assembly benches

Installed at an assembly-bench air drop to clean, regulate and oil-mist the supply feeding air tools and small actuators, with the included bracket mounting the set at the point of use.

Is the GC30008MLC2 AirTAC F.R.L. Combination, PT1/4, Low-Pressure the Right Station?

Start with the size and port: 300 is the mid size in the GC range, and the 08 position gives a 1/4 in port here - step up to 400 or 600 if your line's flow demand points to larger ports, since flow is published as curves rather than one rated figure. Choose the drain to match maintenance practice: this unit has a manual drain, which needs someone to open it periodically; automatic or differential-pressure drains are available if the unit sits where regular attention is impractical. The 40 um element is the standard grade; specify W for the 5 um option where finer filtration is required. The fitted round gauge reads in psi; MPa or bar scales and an embedded square gauge are the other catalogue choices. Thread is PT as standard - order G (BSPP) or NPT if your piping needs them - and the bracket is included. Before ordering, send us the application details and we will confirm sizing against the datasheet flow curves.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

GC30008MLC2 AirTAC F.R.L. Combination, PT1/4, Low-Pressure FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Tell us your application - inlet pressure, set pressure and the equipment being fed - and we will confirm the flow figure from the datasheet on request before you order.

The M in the code GC30008MLC2 specifies a manual drain on the filter bowl, so condensate must be drained by opening the drain periodically. If the unit will be mounted where regular attention is not practical, the catalogue also offers automatic (A) and differential-pressure (blank) drains in the same size - ask us to quote the equivalent model.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30008MLC2 AirTAC F.R.L. Combination, PT1/4, Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30008MLC2 and will confirm price, stock and lead time — usually within 7-8 hours.