AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30010AC2WGK AirTAC F.R.L. Combination Unit, G3/8

The AirTAC GC30010AC2WGK AirTAC F.R.L. Combination Unit, G3/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$108.30 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-10 drain, gauge and thread option on one page All GC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30010AC2WGK AirTAC F.R.L. Combination Unit, G3/8

The AirTAC GC series is a three-piece F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator, assembled as one prepared air supply. This GC30010AC2WGK is the 300 size with a 3/8 in port in G (BSPP) thread. The filter element is the fine 5 um grade (the W option) and the bowl drains automatically, so collected water is expelled without manual attention. The regulator is the standard type with a 0.15-0.9 MPa (20-130 psi) adjustment range, fitted with an external round gauge scaled in psi, and a reverse/check valve is fitted to hold downstream pressure if the supply drops. Mounting bracket included. Bowls on the 300 size are polycarbonate (PC).

This is a genuine AirTAC part. The GC series spans sizes 200, 300, 400 and 600, with port options in PT (standard), G and NPT, drain choices of differential-pressure, automatic or manual, filter grades of 40 um standard or 5 um, gauge scale options, and an optional reverse/check valve. Published flow data appears as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.

GC30010AC2WGK AirTAC F.R.L. Combination Unit, G3/8 Technical Specifications

ModelGC30010AC2WGK AirTAC F.R.L. Combination Unit, G3/8
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30010AC2WGK AirTAC F.R.L. Combination Unit, G3/8

GC300G-series F.R.L. combination, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT3/8" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-10
Build orderFilter → regulator → lubricator

Where the GC30010AC2WGK AirTAC F.R.L. Combination Unit, G3/8 Is Used

precision_manufacturing

CNC machining cell air supply

Feeds clean, regulated and lubricated air to the tool-changer and clamping cylinders on a CNC machining centre, with the 5 um element protecting fine control valves from particulate carryover.

conveyor_belt

Packaging line conveyor actuation

Prepares the air feeding stopper, pusher and diverting cylinders along a carton packaging conveyor, with automatic drainage coping with condensate that collects over continuous shifts.

factory

Assembly plant air-tool drop

Serves a drop point supplying impact wrenches and air ratchets at an assembly-plant workstation, where the lubricator carries oil mist to the tools and the regulator holds a steady set pressure.

Is the GC30010AC2WGK AirTAC F.R.L. Combination Unit, G3/8 the Right Station?

Start with the port step: the 300 size carries 3/8 in ports; step up to 400 or 600, or down to 200, as your line's flow demand dictates - we will check the published flow curves against your consumption before you order. Choose the drain: automatic (as coded here) suits unattended duty, manual suits supervised points, and differential-pressure is the default where a pressure drop can trigger the drain. Filter grade is 40 um standard; the W code gives this finer 5 um element for sensitive downstream equipment. Gauge scale is selectable (MPa, psi or bar) and the round external gauge is optional against the embedded square type. Thread is PT as standard, with G and NPT as order options - this unit is coded G. A reverse/check valve (K) is available where holding downstream pressure matters, and a mounting bracket can be included or omitted.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.

GC30010AC2WGK AirTAC F.R.L. Combination Unit, G3/8 FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote one number. Send us your line's air consumption and operating pressure and we will confirm the datasheet flow figures for this 300-size, 3/8 in unit on request before you order.

The A code means the filter bowl drains itself once collected condensate reaches a set level, with no manual intervention - useful for unattended or hard-to-reach installations. The alternatives are manual draining (code M) and the differential-pressure default; all three are order choices on the GC series, and this unit is supplied with the automatic drain.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30010AC2WGK AirTAC F.R.L. Combination Unit, G3/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30010AC2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.