The AirTAC GC30010ALC2K AirTAC F.R.L. Combination, PT3/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC30010ALC2K is an AirTAC GC three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one supply package. This configuration is sized for 3/8 in PT ports. The filter element is the standard 40 um grade and the bowl drains automatically, so collected water is expelled without manual attention. The regulator is the low-pressure type, and the unit carries an external round gauge reading in psi. A reverse/check valve is fitted, and the mounting bracket is included. The filter and lubricator bowls are polycarbonate (PC).
This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600, with port options from 1/8 in to 1 in, G or NPT thread variants, manual or differential-pressure drain choices, a 5 um filter grade (code W), gauge scale options and reverse-valve variants. Flow is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GC30010ALC2K AirTAC F.R.L. Combination, PT3/8 |
|---|---|
| Series | GC300 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/8" (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC300 | G-series F.R.L. combination, 300 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC300 · PT3/8" · 40 µm |
|---|---|
| One size down | GC200 |
| One size up | GC400 |
| Two-unit equivalent | GFC300-10 |
| Build order | Filter → regulator → lubricator |
Feeding clean, regulated and lubricated air to the pneumatic cylinders and actuators on a carton-forming and sealing line, with automatic drain keeping condensate off the line between shifts.
Supplying the air cylinders that raise, divert and stop product on a conveyor system, where the low-pressure regulator type matches lower working pressures and the psi gauge gives operators a direct reading.
Conditioning the air feeding grippers and test fixtures on a laboratory automation bench, with the reverse/check valve holding downstream pressure and the bracket giving tidy panel mounting.
Start with the port size: this unit steps up to 3/8 in PT, and the GC range runs from size 200 (1/8 in, 1/4 in) through 300 and 400 up to size 600 (3/4 in, 1 in), so match the size step to the air demand of the circuit. Drain choice matters: automatic drain (this unit) suits installations that are not checked daily, while manual and differential-pressure drain types are available in the family. Filter grade is 40 um standard; specify the W code for 5 um where finer filtration is needed. The gauge here is an external round gauge reading psi; embedded square gauges and MPa or bar scales are the other options. Thread is PT as standard, with G (BSPP) and NPT available as order options; the mounting bracket is included on this unit. Note that this is the low-pressure regulator type, so confirm the control range against your working pressure before ordering. Because flow is published as curves rather than a single rating, send us your application details and we will confirm sizing from the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Send us your application details - working pressure and expected air demand - and we will confirm the flow figures from the datasheet on request before you order.
The K code means a reverse/check valve is fitted, so air will not back-flow through the unit when upstream supply is lost. The A code means the filter bowl drains automatically, expelling collected condensate without manual intervention - useful where the unit is mounted in a position that is not checked daily. Both are factory-fitted options on this configuration.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.