AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30010MF2G AirTAC F.R.L. Unit, G3/8, Manual Drain

The AirTAC GC30010MF2G AirTAC F.R.L. Unit, G3/8, Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$86.71 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-10 drain, gauge and thread option on one page All GC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30010MF2G AirTAC F.R.L. Unit, G3/8, Manual Drain

The GC30010MF2G is a three-piece AirTAC F.R.L. combination: a separate filter, regulator and lubricator assembled as one air-preparation unit. The filter removes water and particulate down to 40 um, the regulator holds a steady downstream pressure adjustable from 0.05 to 0.9 MPa (7-130 psi), and the lubricator adds oil mist for downstream air tools and actuators. This configuration has a G3/8 (BSPP) port, a manual drain on the filter bowl, a square pressure gauge scaled in psi, and a mounting bracket included. The maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). The bowls on this 300 size are polycarbonate (PC).

This is a genuine AirTAC part. The GC family is available in 200, 300, 400 and 600 sizes with port sizes from 1/8 to 1 inch, and options including automatic or differential-pressure drains, a 5 um filter element (code W), gauge scale in MPa, psi or bar, and G or NPT threads in place of the PT standard. Published flow data appears as curves rather than a single rating, so we confirm flow and datasheet figures on request.

GC30010MF2G AirTAC F.R.L. Unit, G3/8, Manual Drain Technical Specifications

ModelGC30010MF2G AirTAC F.R.L. Unit, G3/8, Manual Drain
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30010MF2G AirTAC F.R.L. Unit, G3/8, Manual Drain

GC300G-series F.R.L. combination, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT3/8" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-10
Build orderFilter → regulator → lubricator

Where the GC30010MF2G AirTAC F.R.L. Unit, G3/8, Manual Drain Is Used

factory

Pneumatic press line preparation

Feeding filtered, regulated and lubricated air to a pneumatic press or clamping station, where clean dry air protects valves and cylinders and steady regulated pressure keeps cycle force consistent.

conveyor_belt

Packaging machinery air supply

Supplying air to packaging and cartoning machines with air cylinders and air-driven grippers, where the lubricator keeps seals and moving parts running and the 40 um filter stops debris reaching the valves.

settings_input_component

Assembly station tool feed

Conditioning the air feed to a bench assembly station running air impact drivers and nutrunners, with the square psi gauge letting operators set and check working pressure at a glance.

Is the GC30010MF2G AirTAC F.R.L. Unit, G3/8, Manual Drain the Right Station?

Start with the size and port: the 300 size carries a G3/8 port, and stepping up to 400 or 600 gives larger ports and more flow capacity, while 200 suits smaller lines. Choose the drain type for the filter bowl: manual drain (as fitted here) needs periodic draining by hand, automatic drain handles condensate on its own, and differential-pressure drain is the default. The 40 um element is standard; specify the W code for a 5 um element where finer filtration is needed. The embedded square gauge is standard with a psi scale on this unit; MPa or bar scales and an external round gauge are options. Thread is G (BSPP) on this model; PT is the standard and NPT is an order option. A mounting bracket is included.

Flow for this family is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.

GC30010MF2G AirTAC F.R.L. Unit, G3/8, Manual Drain FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a rated flow number. Send us your application details and we will confirm the flow and sizing from the datasheet on request.

The M in the code GC30010MF2G specifies a manual drain on the filter bowl, which means condensate is drained by hand at intervals. If you prefer the bowl to discharge condensate automatically, the A code gives an automatic drain, and the default blank code gives a differential-pressure drain. The regulator adjustment range also differs: with manual drain it is 0.05-0.9 MPa (7-130 psi), while with automatic or differential-pressure drain it is 0.15-0.9 MPa (20-130 psi).

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30010MF2G AirTAC F.R.L. Unit, G3/8, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30010MF2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.