verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30010MLC2 AirTAC F.R.L. Combination, PT3/8, Low-Pressure

The AirTAC GC30010MLC2 AirTAC F.R.L. Combination, PT3/8, Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$87.35 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30010MLC2 AirTAC F.R.L. Combination, PT3/8, Low-Pressure

The GC30010MLC2 is a three-piece AirTAC GC air-treatment combination: a separate air filter, a pressure regulator and an oil-mist lubricator assembled as one F.R.L. set. This size 300 configuration is threaded PT3/8 (3/8 in), carries a 40 um filter element with a manual drain, and is built as the low-pressure regulator type. The round pressure gauge fitted to this code reads in psi, and the mounting bracket is included. The filter and lubricator bowls are polycarbonate (PC).

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and with options including automatic or manual drains, a 5 um filter element (code W), gauge scales in MPa, psi or bar, and G (BSPP) or NPT threads in place of the PT standard. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm sizing figures from the datasheet for your application.

GC30010MLC2 AirTAC F.R.L. Combination, PT3/8, Low-Pressure Technical Specifications

ModelGC30010MLC2 AirTAC F.R.L. Combination, PT3/8, Low-Pressure
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (PT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30010MLC2 AirTAC F.R.L. Combination, PT3/8, Low-Pressure

GC300G-series F.R.L. combination, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-10 filter, GR300-10 regulator and GL300-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT3/8" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-10
Build orderFilter → regulator → lubricator

Where the GC30010MLC2 AirTAC F.R.L. Combination, PT3/8, Low-Pressure Is Used

factory

Cartoning line air supply

Feeding clean, regulated and lubricated air to the cylinders and grippers on a carton-forming line, with the manual drain emptied during scheduled shift checks.

precision_manufacturing

Pneumatic press station

Air preparation ahead of a small pneumatic press or clamping fixture, where the regulator holds a steady set pressure and the lubricator mists the cylinder seals.

conveyor_belt

Conveyor stopper cylinders

Conditioning supply air for stoppers and pushers along a conveyor run, with the 40 um element catching pipe scale and the psi gauge giving operators a visible line pressure.

Is the GC30010MLC2 AirTAC F.R.L. Combination, PT3/8, Low-Pressure the Right Station?

The real choices in this series are decodable from the code. Step the size (200/300/400/600) and port (1/8 in to 1 in) against the air demand of the circuit - larger sizes carry more flow, and we will confirm the curve for the size you are considering. Drain type: this unit is manual drain; automatic and differential-pressure drains are available if you cannot rely on regular manual draining. Filter grade: the 40 um element is standard here; a 5 um element (code W) suits more sensitive downstream equipment. Gauge: this code carries a round gauge reading psi; embedded square gauges and MPa or bar scales are alternatives. Thread: PT is the standard on this unit, with G (BSPP) and NPT as orderable options. Note that this is the low-pressure regulator type; its exact adjustment range is not published in the material we hold, so confirm it with us before ordering if your set pressure is critical. Flow is published as curves, not a single rating, so ask us to check sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-10 regulator with a GF300-10 filter on that branch.

GC30010MLC2 AirTAC F.R.L. Combination, PT3/8, Low-Pressure FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Tell us your working pressure and air demand and we will confirm the sizing from the datasheet before you order.

The M in the code sets the manual drain: someone opens the drain valve to empty collected water from the filter bowl. If the unit is mounted where regular draining is impractical, the same size is available with an automatic or differential-pressure drain - ask us for that variant.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30010MLC2 AirTAC F.R.L. Combination, PT3/8, Low-Pressure