verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30015AC2W AirTAC F.R.L. Combination, PT1/2, 5 um

The AirTAC GC30015AC2W AirTAC F.R.L. Combination, PT1/2, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$97.45 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30015AC2W AirTAC F.R.L. Combination, PT1/2, 5 um

The GC30015AC2W is an AirTAC GC-series three-unit F.R.L. combination: a separate filter, regulator and lubricator assembled as one air-preparation set. This configuration is the GC300 size with a PT1/2 (1/2 in) PT-threaded port, fitted with a 5 um filter element (code W, versus the standard 40 um) and an automatic drain on the filter bowl, so condensate is ejected without manual attention. The regulator is the standard type with a 0.15-0.9 MPa (20-130 psi) adjustment range, and this unit carries a round gauge reading in psi; the embedded square gauge is the standard fitting and an external round gauge is the optional alternative. The polycarbonate bowls suit the 300 size (only the 600 size uses aluminium alloy), and a mounting bracket is included.

This is a genuine AirTAC part. The GC family spans the 200, 300, 400 and 600 sizes with port sizes from 1/8 in to 1 in, and options for drain type (differential-pressure, automatic or manual), filter grade (40 um standard, 5 um with W), gauge style and scale, PT, G or NPT thread, and a reverse/check valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.

GC30015AC2W AirTAC F.R.L. Combination, PT1/2, 5 um Technical Specifications

ModelGC30015AC2W AirTAC F.R.L. Combination, PT1/2, 5 um
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30015AC2W AirTAC F.R.L. Combination, PT1/2, 5 um

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the GC30015AC2W AirTAC F.R.L. Combination, PT1/2, 5 um Is Used

factory

Automotive assembly cell air supply

Feeding impact wrenches, nutrunners and air cylinders at an assembly station: the filter removes water and 5 um particulate, the regulator holds a steady set pressure for consistent tool torque, and the lubricator carries oil mist to the tools.

precision_manufacturing

CNC machine shop pneumatic clamping

Supplying the clamps, tool-change cylinders and air-blast circuits on a machining centre, where the regulator keeps clamp force repeatable and the automatic drain keeps condensate out of the valve stack.

conveyor_belt

Carton-forming packaging line

Preparing air for the cylinders and air jets on a case-packing conveyor, with the 5 um element protecting directional valves and the lubricator extending the life of the cylinder seals.

Is the GC30015AC2W AirTAC F.R.L. Combination, PT1/2, 5 um the Right Station?

Start with the size and port: the GC300 with its PT1/2 port is the mid-range step of the four GC sizes (200/300/400/600), and the right choice depends on the air demand of the downstream circuit - step up a size for higher flow rather than throttling a smaller unit. This code already fixes several real choices: automatic drain (no routine draining of the bowl), 5 um filtration where finer particulate removal is wanted over the 40 um standard, a round psi-scale gauge, PT thread (G/BSPP and NPT are orderable options), and an included bracket. The regulator adjusts 0.15-0.9 MPa (20-130 psi) with a maximum inlet of 1.0 MPa (145 psi), and the set operates from -5 to 70 C in non-freezing conditions.

On sizing, be aware that catalogue flow is published as curves, not a single rated number, so we do not quote a flow figure here. Send us your line pressure, set pressure and expected air consumption, and we will confirm the correct size against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

GC30015AC2W AirTAC F.R.L. Combination, PT1/2, 5 um FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not state a flow number. Tell us your line pressure, set pressure and expected air consumption, and we will confirm the sizing against the datasheet on request before you order.

The W in the code GC30015AC2W selects the 5 um element instead of the 40 um standard, giving finer particulate removal for sensitive downstream equipment. The A selects the automatic drain, which ejects collected condensate from the filter bowl without manual draining; the differential-pressure drain is the default if you prefer it, and a manual-drain version is also available in the family.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30015AC2W AirTAC F.R.L. Combination, PT1/2, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015AC2W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.