verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30015AC2WGK AirTAC F.R.L. Unit G1/2 5 um

The AirTAC GC30015AC2WGK AirTAC F.R.L. Unit G1/2 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$108.30 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30015AC2WGK AirTAC F.R.L. Unit G1/2 5 um

The AirTAC GC30015AC2WGK is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one air-treatment set. This configuration is built around a G1/2 port, a 5 um filter element for finer protection than the standard 40 um grade, and an automatic drain that expels collected condensate from the filter bowl without manual attention. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi), and an external round gauge with a psi scale is fitted so downstream pressure can be read directly. A reverse/check valve is included, and the mounting bracket is supplied.

This is a genuine AirTAC part from the GC series, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, plus choices of drain type, filter grade, gauge scale and thread form (PT standard, G and NPT as order options). Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.

GC30015AC2WGK AirTAC F.R.L. Unit G1/2 5 um Technical Specifications

ModelGC30015AC2WGK AirTAC F.R.L. Unit G1/2 5 um
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30015AC2WGK AirTAC F.R.L. Unit G1/2 5 um

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the GC30015AC2WGK AirTAC F.R.L. Unit G1/2 5 um Is Used

precision_manufacturing

CNC machining cell air supply

Feeds filtered, regulated and lubricated air to the clamping fixtures, tool-change cylinders and air-powered spindles of a machining centre, where the 5 um element protects fine valve seats and the check valve holds downstream pressure if the main supply dips.

conveyor_belt

Packaging line actuator supply

Conditions the air feeding the cylinders and air-jet nozzles on a carton-forming and sealing conveyor, with the lubricator metering oil mist to extend cylinder seal life and the automatic drain clearing condensate on a line that runs unattended.

factory

Assembly plant point-of-use station

Installed as a drop-leg treatment station at a plant workbench, giving operators a regulated, lubricated and finely filtered air supply for air tools and small actuators, with the psi gauge letting the station be set and checked at a glance.

Is the GC30015AC2WGK AirTAC F.R.L. Unit G1/2 5 um the Right Station?

Start with the port and size step: this unit is size 300 with a G1/2 port, and larger sizes carry larger ports and more flow capacity, so match the step to the air demand of the circuit rather than oversizing on guesswork. The 5 um element (code W) suits applications that need finer particulate removal than the standard 40 um grade; the automatic drain is the right choice where the unit is not visited daily, while manual and differential-pressure drains remain available in the series. The fitted round gauge reads in psi; square embedded gauges and MPa or bar scales are the other catalogue options. Thread is G here, with PT as the standard form and NPT available to order. Because flow is published as curves and not as a single rating, send us your application details and we will confirm the sizing against the datasheet before you commit.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

GC30015AC2WGK AirTAC F.R.L. Unit G1/2 5 um FAQ

AirTAC publishes flow for the GC series as capacity curves, not as a single rated number, so we do not quote a figure that could be misleading. Tell us your application and operating pressure and we will confirm the flow data from the datasheet on request before you order.

The A code in this model fits the automatic drain, which discharges condensate from the filter bowl by itself and suits units mounted in awkward or rarely visited positions. The series also offers a manual drain for supervised points and a differential-pressure drain as the default; all three share the same 0.15-0.9 MPa (20-130 psi) regulation range on this configuration.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30015AC2WGK AirTAC F.R.L. Unit G1/2 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015AC2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.