The AirTAC GC30015AF2 AirTAC F.R.L. Combination, PT1/2, Auto Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$97.44 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30015AF2 AirTAC F.R.L. Combination, PT1/2, Auto Drain

The GC30015AF2 is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one 300-size set. This configuration is decodes to PT1/2 ports (1/2 in) with the PT thread as standard, a 40 um filter element, an automatic drain on the filter bowl, and a fitted square gauge reading in psi. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi), and the polycarbonate bowls give a clear view of condensate and oil level. Maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GC series is available in 200, 300, 400 and 600 sizes with port sizes from 1/8 in to 1 in, and with options including a 5 um filter element (code W), manual or automatic drain, G (BSPP) or NPT threads, gauge scale in MPa, psi or bar, and a reverse/check valve. Flow is published as curves rather than a single rated figure, so we confirm flow and datasheet figures on request before you order.

GC30015AF2 AirTAC F.R.L. Combination, PT1/2, Auto Drain Technical Specifications

ModelGC30015AF2 AirTAC F.R.L. Combination, PT1/2, Auto Drain
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30015AF2 AirTAC F.R.L. Combination, PT1/2, Auto Drain

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the GC30015AF2 AirTAC F.R.L. Combination, PT1/2, Auto Drain Is Used

factory

Automated assembly line air supply

Feeding a production cell where clean, regulated and lubricated air reaches cylinders, grippers and air tools together, with the automatic drain removing condensate without an operator having to visit the set each shift.

precision_manufacturing

CNC machine shop pneumatic drops

Supplying individual machine tools from a shop air main, where the 40 um filter protects directional valves, the regulator holds a steady setting shown on the psi gauge, and the lubricator mists oil to air cylinders and chucks.

conveyor_belt

Packaging and conveyor systems

Conditioning the air feeding conveyor diverters, case sealers and bagging machinery, where steady regulated pressure and light lubrication keep actuators cycling reliably through long production runs.

Is the GC30015AF2 AirTAC F.R.L. Combination, PT1/2, Auto Drain the Right Station?

Start with the size and port step: 300-size units carry PT1/2 ports, and larger sizes (400, 600) move to bigger ports and higher flow capacity, so match the size to the air demand of the machines downstream. Choose the drain type where it applies: automatic drain suits unattended or hard-to-reach installations, manual drain suits stations visited daily, and the differential-pressure type is the default. Filter grade is 40 um as standard for general line protection, or 5 um (code W) where finer particle removal is needed ahead of valves and actuators. Gauge scale can be ordered in MPa, psi or bar, and thread options are PT (standard), G (BSPP) or NPT. Flow for this series is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

GC30015AF2 AirTAC F.R.L. Combination, PT1/2, Auto Drain FAQ

AirTAC publishes flow for this series as curves rather than a single rated figure, so there is no one rated flow number we can quote. Send us your application details and we will confirm the flow and full datasheet figures for the GC30015AF2 on request before you order.

The A in the code GC30015AF2 means the filter bowl carries an automatic drain, which expels collected condensate without manual attention - useful for installations that are not checked daily. Manual-drain and differential-pressure-drain versions are available in the same series if you prefer a different arrangement.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30015AF2 AirTAC F.R.L. Combination, PT1/2, Auto Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015AF2 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.