verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30015ALC2GK AirTAC F.R.L. Combination G1/2

The AirTAC GC30015ALC2GK AirTAC F.R.L. Combination G1/2 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$108.44 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30015ALC2GK AirTAC F.R.L. Combination G1/2

The GC30015ALC2GK is a three-piece AirTAC GC-series F.R.L. combination: a filter, a pressure regulator and an oil-mist lubricator assembled as one air-preparation set. This size 300 unit is ported G1/2 (BSPP) as coded - PT is the catalogue standard thread, with G and NPT as order options. The filter section carries the standard 40 um element with an automatic drain, the regulator is the low-pressure type, an external round gauge scaled in psi is fitted, and a reverse/check valve and mounting bracket are included. The filter and lubricator bowls are polycarbonate at this size.

This is a genuine AirTAC part. The GC range is available in sizes 200, 300, 400 and 600, with a choice of drain type (differential-pressure, automatic or manual), 40 um or 5 um (W) filtration, gauge scale in MPa, psi or bar, and PT, G or NPT threads. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.

GC30015ALC2GK AirTAC F.R.L. Combination G1/2 Technical Specifications

ModelGC30015ALC2GK AirTAC F.R.L. Combination G1/2
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30015ALC2GK AirTAC F.R.L. Combination G1/2

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the GC30015ALC2GK AirTAC F.R.L. Combination G1/2 Is Used

precision_manufacturing

CNC machining cell air prep

Filter, regulate and lubricate the shop-air feed to a CNC cell's pneumatic clamps, tool-change cylinders and blow-off nozzles from a single G1/2 drop.

conveyor_belt

Bottling line conveyor actuators

Condition the air feeding stopper cylinders, diverters and gate actuators along a bottling conveyor, with the automatic drain handling condensate at the drop.

factory

Assembly plant air-tool stations

Supply regulated, oil-mist lubricated air to impact wrenches and nutrunners at a vehicle assembly station, with the check valve blocking backflow through the set.

Is the GC30015ALC2GK AirTAC F.R.L. Combination G1/2 the Right Station?

Size 300 with G1/2 ports sits mid-range in the GC line; step up to 400/600 or down to 200 depending on the air demand of your circuit - we can check the published flow curves against your requirement before you order. Drain type matters: automatic empties the filter bowl without attention, manual relies on a routine drain, and the differential-pressure default suits steady duty. Filtration here is the 40 um standard element; specify W for a 5 um grade. The fitted round gauge reads in psi; the embedded square gauge is the standard alternative, with MPa or bar scales orderable. Thread on this code is G (BSPP); PT is the standard and NPT is orderable. Mounting bracket is included. Note the regulator is the low-pressure type (L); its exact adjustment range is not published, so confirm it with us before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

GC30015ALC2GK AirTAC F.R.L. Combination G1/2 FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so there is no one rated-flow number we can quote. Send us your line pressure and air demand and we will confirm the sizing from the datasheet before you order.

L marks the low-pressure regulator type, intended for circuits running below standard line pressure; its exact adjustment range is not published, so confirm it with us. C2 means an external round gauge scaled in psi is fitted - the embedded square gauge is the standard alternative, with MPa or bar scales orderable.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30015ALC2GK AirTAC F.R.L. Combination G1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015ALC2GK and will confirm price, stock and lead time — usually within 7-8 hours.