verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30015ALF2WG AirTAC F.R.L. Combination, G1/2, 5 um

The AirTAC GC30015ALF2WG AirTAC F.R.L. Combination, G1/2, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$97.11 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30015ALF2WG AirTAC F.R.L. Combination, G1/2, 5 um

The AirTAC GC30015ALF2WG is a three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one treatment stack. This configuration is built on the GC300 size with G1/2 (BSPP) ports, a 5 um filter element (the finer W grade instead of the standard 40 um), an automatic drain on the filter bowl so collected condensate is expelled without manual attention, and a low-pressure-type regulator fitted with an embedded square gauge scaled in psi. The filter and regulator bowls are polycarbonate, and the unit is supplied with a mounting bracket. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with a choice of ports, drain types, filter grades, gauge scales and thread options (PT standard; G and NPT as order options). Because flow is published as curves rather than a single rating, we confirm flow and other datasheet figures for your application on request before you order.

GC30015ALF2WG AirTAC F.R.L. Combination, G1/2, 5 um Technical Specifications

ModelGC30015ALF2WG AirTAC F.R.L. Combination, G1/2, 5 um
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30015ALF2WG AirTAC F.R.L. Combination, G1/2, 5 um

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the GC30015ALF2WG AirTAC F.R.L. Combination, G1/2, 5 um Is Used

factory

Automotive paint shop air supply

Feeds filtered, regulated and lubricated air to spray guns and air-assisted applicators on a paint line, where the 5 um element protects finish quality and the low-pressure regulator suits gentle atomising setpoints.

conveyor_belt

Bottling line conveyor cylinders

Conditions the air feeding pneumatic cylinders and grippers along a bottling or packaging conveyor, keeping water and grit out of the valves while the lubricator maintains smooth cylinder operation through long shifts.

precision_manufacturing

CNC fixture clamping circuit

Supplies treated air to pneumatic clamps and tool-change actuators on a machining centre, with the automatic drain handling condensate from humid shop air and the psi gauge giving operators a familiar setpoint readout.

Is the GC30015ALF2WG AirTAC F.R.L. Combination, G1/2, 5 um the Right Station?

Start with size and port: the GC series steps through sizes 200, 300, 400 and 600, and each size maps to a port (here size 300 with a 1/2 in port), so pick the step that matches your line's flow demand and existing piping. Then set the drain: automatic (this unit) empties the filter bowl on its own, while manual and differential-pressure drains suit other service patterns. Choose the filter grade - 40 um standard or 5 um (W) where finer particulate removal matters - and the gauge scale (MPa, psi or bar). Thread is PT as standard with G (BSPP) and NPT as catalogue options; this unit carries the G thread. Note that this is the low-pressure (L) type regulator, so confirm its adjustment range against your setpoint. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

GC30015ALF2WG AirTAC F.R.L. Combination, G1/2, 5 um FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a rated flow number. Tell us your line pressure and the air demand of your equipment and we will confirm the correct size from the datasheet curves on request before you order.

L marks the low-pressure type of regulator in this combination. It is intended for lower setpoint applications than the standard type; the exact adjustment range for the low-pressure version is not published in the material we hold, so confirm your required setpoint with us and we will verify it on request. The unit also carries an embedded square gauge scaled in psi, with MPa or bar scales available as options.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30015ALF2WG AirTAC F.R.L. Combination, G1/2, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015ALF2WG and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.