verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30015F2WGK AirTAC F.R.L. Combination, G1/2, 5 um

The AirTAC GC30015F2WGK AirTAC F.R.L. Combination, G1/2, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$97.95 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30015F2WGK AirTAC F.R.L. Combination, G1/2, 5 um

The GC30015F2WGK is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one complete air-treatment set. This configuration is built for 1/2 in ports with G (BSPP) threads, carries the W fine-filtration element rated at 5 um, and drains condensate by the differential-pressure method. The regulator is the standard type with a 0.15-0.9 MPa (20-130 psi) adjustment range, a square gauge graduated in psi is fitted, and a reverse/check valve is included so downstream pressure is held if the supply line is lost. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). The filter and lubricator bowls on this size are PC (polycarbonate).

This is a genuine AirTAC part. The GC combination is available in sizes 200, 300, 400 and 600 with a choice of ports and threads, drain types, 40 um or 5 um filtration, gauge style and scale, and with or without a reverse/check valve. Flow is published in the catalogue as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.

GC30015F2WGK AirTAC F.R.L. Combination, G1/2, 5 um Technical Specifications

ModelGC30015F2WGK AirTAC F.R.L. Combination, G1/2, 5 um
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30015F2WGK AirTAC F.R.L. Combination, G1/2, 5 um

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the GC30015F2WGK AirTAC F.R.L. Combination, G1/2, 5 um Is Used

factory

Paint and finishing shop air drops

A 5 um element ahead of spray guns and air-assisted applicators keeps water and fine particulate out of the finish, while the lubricator mists oil to the air motors and the regulator holds a steady gun pressure on a 1/2 in drop.

precision_manufacturing

Pneumatic press and clamp circuits

Feeding clamps, grippers and small pneumatic presses on an automation cell: the regulator holds set clamping pressure, the reverse/check valve holds it if the main supply drops, and the 5 um element protects the directional valves.

conveyor_belt

Packaging line air cylinders

A complete F.R.L. set at the header of a packaging or palletising line, conditioning the air feeding conveyor diverters, case erectors and cylinder-driven sealers, with the lubricator keeping cylinder seals and valve spools oiled.

Is the GC30015F2WGK AirTAC F.R.L. Combination, G1/2, 5 um the Right Station?

Sizing starts with the port step: this unit is the 300 size with 1/2 in ports, so match it against the flow your line actually needs - the catalogue publishes flow as curves, not one rated number, so send us your demand and we will confirm the right size. Filtration here is the 5 um (W) element; choose it when downstream valves and cylinders need finer protection than the 40 um standard element provides. The differential-pressure drain flushes condensate automatically as the pressure differential across the element builds, with no operator attention; if you prefer a timed or fully automatic drain, other GC configurations cover those options.

The fitted square gauge reads in psi, with MPa and bar scales available on other variants, and an external round gauge is an option if you prefer panel-side visibility. Threads are G (BSPP) on this code; PT is the standard thread and NPT is also a catalogue option. A mounting bracket is included, and the reverse/check valve (K) holds the regulated downstream pressure on air failure.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

GC30015F2WGK AirTAC F.R.L. Combination, G1/2, 5 um FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote one number. Tell us your line pressure and the air demand of the equipment you are feeding, and we will confirm the sizing against the datasheet curves for this 300-size, 1/2 in unit before you order.

The W in the code specifies the 5 um element instead of the 40 um standard, giving finer protection for downstream valves, cylinders and tools. The K specifies a reverse/check valve, which holds the regulated downstream pressure if the upstream supply is interrupted. Both are decodable choices on the GC series, and the gauge fitted here is the embedded square type reading in psi.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30015F2WGK AirTAC F.R.L. Combination, G1/2, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015F2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.