verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30015LF2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure

The AirTAC GC30015LF2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$87.24 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30015LF2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure

The AirTAC GC30015LF2 is a three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator, each doing its own job on one compressed-air line. The filter element removes water and particulate down to 40 um, the differential-pressure drain bleeds collected condensate as flow creates a pressure drop across the element, the low-pressure regulator sets a reduced working pressure downstream, and the lubricator meters oil mist into the air for downstream pneumatic tools and cylinders. This configuration is the 300 size with PT1/2 ports, a square gauge reading in psi, PC (polycarbonate) bowls, a mounting bracket, and no reverse/check valve.

This is a genuine AirTAC part. The GC series is offered in sizes 200, 300, 400 and 600 with a choice of ports, drain types (differential-pressure, automatic or manual), a 5 um element option (code W), gauge scale and thread options including G and NPT alongside the PT standard. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application on request.

GC30015LF2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure Technical Specifications

ModelGC30015LF2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30015LF2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the GC30015LF2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure Is Used

factory

Automotive paint-shop air drops

Feeds spray-gun drops on a paint line where the filter strips water and pipe scale, the regulator holds a steady low working pressure at the gun, and the lubricator is set to zero or a light mist depending on the gun type.

precision_manufacturing

CNC machine pneumatic supply

Conditions the shop-air feed to a machining centre's clamps, tool-changer cylinders and air-blast circuits, giving the maintenance team one point to drain, set pressure and top up oil.

conveyor_belt

Packaging-line conveyor cylinders

Supplies filtered, regulated and lubricated air to the diverters, pushers and gripper cylinders along a packaging conveyor, protecting the actuators from moisture and dirt in a shared mill air ring main.

Is the GC30015LF2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure the Right Station?

Start with the port and size step: 200, 300, 400 and 600 step up in port and flow capacity, so match the size to the air demand of the line rather than only the existing pipe thread - here the 300 size gives PT1/2. Then choose the drain: differential-pressure (this model) drains with flow, automatic (code A) drains without intervention, and manual (code M) is emptied by hand. If finer filtration is needed, the 5 um element (code W) replaces the 40 um standard. Gauge scale is selectable (MPa, psi or bar - this unit carries the square psi gauge), and thread can be ordered as PT (standard), G (BSPP) or NPT. A bracket is included on this configuration.

One honest note before ordering: AirTAC publishes flow for this series as curves, not as a single rated number, and the exact regulation range of the low-pressure type is not stated in the published figures we hold. Send us your line pressure, required downstream pressure and air demand, and we will confirm the datasheet figures and correct sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

GC30015LF2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote one number. Tell us your inlet pressure, required downstream pressure and air demand, and we will confirm the datasheet curve and check the sizing for your application on request. The same applies to the exact regulation range of the low-pressure regulator type fitted to this model.

This GC30015LF2 carries the differential-pressure drain (the default): when air flows through the filter element, the pressure drop across it opens the drain and collected condensate is bled off automatically during operation. If your line runs intermittently at low flow, an automatic drain (code A) or a manual drain (code M) may suit better - both are orderable options in the same size.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30015LF2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015LF2 and will confirm price, stock and lead time — usually within 7-8 hours.