verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30015LF2WK AirTAC F.R.L. Combination, PT1/2

The AirTAC GC30015LF2WK AirTAC F.R.L. Combination, PT1/2 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$98.60 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30015LF2WK AirTAC F.R.L. Combination, PT1/2

The GC30015LF2WK is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator assembled as one 300-size unit for 1/2 in PT ports. In use, the filter element removes water and particulate down to 5 um (the finer W grade, versus the 40 um standard), the low-pressure-type regulator holds a stable downstream setting, and the lubricator meters oil mist into the air line. This configuration carries the differential-pressure drain on the filter bowl, a square pressure gauge reading in psi, a reverse/check valve, and a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C, non-freezing. The bowls on the 300 size are PC (polycarbonate).

This is a genuine AirTAC part. The GC family is offered in 200, 300, 400 and 600 sizes with port sizes from 1/8 in to 1 in, and with choices of drain type, filter grade, gauge style and scale, thread (PT standard, G and NPT as order options) and reverse valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.

GC30015LF2WK AirTAC F.R.L. Combination, PT1/2 Technical Specifications

ModelGC30015LF2WK AirTAC F.R.L. Combination, PT1/2
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30015LF2WK AirTAC F.R.L. Combination, PT1/2

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the GC30015LF2WK AirTAC F.R.L. Combination, PT1/2 Is Used

precision_manufacturing

CNC machining centre air supply

Feeds filtered, regulated and lubricated air to the tool-changer, clamps and pneumatic actuators on a CNC machining centre, with the 5 um element protecting fine control valves on the machine's air train.

conveyor_belt

Packaging line cylinder circuits

Supplies the diverters, sealers and pusher cylinders on a carton packaging line, where the lubricator keeps cylinder seals running smoothly and the low-pressure regulator suits circuits set well below full line pressure.

factory

Textile plant drop lines

Installed as a point-of-use F.R.L. on drop lines serving looms and winding machines, conditioning the shop air at each machine and draining accumulated condensate automatically via the differential-pressure drain.

Is the GC30015LF2WK AirTAC F.R.L. Combination, PT1/2 the Right Station?

Start with the port step: this unit is 300 size with a 1/2 in PT port; step up to 400 or 600 if the line needs more flow capacity, or down to 200 for compact supply points. Filter grade is your next choice: the W code here selects the 5 um element for finer air, while the blank default is 40 um for general-purpose protection. Drain type on the filter bowl is differential-pressure as standard, with automatic (A) and manual (M) variants available. The gauge here is the embedded square type reading psi; an external round gauge with MPa, psi or bar scale is optional. Thread is PT as standard, with G (BSPP) and NPT available to order, and a bracket is included. Note this is the low-pressure regulator type (L), and a reverse/check valve (K) is fitted. Because flow is published as curves and not a single rating, send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

GC30015LF2WK AirTAC F.R.L. Combination, PT1/2 FAQ

AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote a number. Tell us your line pressure and the flow your equipment needs, and we will confirm the sizing against the datasheet on request before you order.

The W code in GC30015LF2WK selects the optional 5 um element instead of the 40 um standard, for finer removal of water and particulate ahead of the regulator and lubricator. The K code adds a reverse/check valve, and the L code makes this the low-pressure regulator type. The filter bowl drains by differential pressure, and the square gauge reads psi.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30015LF2WK AirTAC F.R.L. Combination, PT1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015LF2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.