verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30015MC2G AirTAC F.R.L. Combination, G1/2, Manual Drain

The AirTAC GC30015MC2G AirTAC F.R.L. Combination, G1/2, Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$86.70 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30015MC2G AirTAC F.R.L. Combination, G1/2, Manual Drain

The GC30015MC2G is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one unit. This configuration is sized at 300 with 1/2 in ports threaded G (BSPP), carries the standard 40 um filter element, and uses a manual drain on the filter bowl, so an operator drains collected water by hand as part of routine checks. The regulator is the standard type with an adjustment range of 0.05-0.9 MPa (7-130 psi), and a round external gauge scaled in psi is fitted so the set pressure can be read directly at the unit. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). The bowls on the filter and lubricator are PC (polycarbonate) at this size.

This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600 with matching port sizes, and options include a 5 um filter element (code W), automatic or differential-pressure drain in place of manual, gauge scale in MPa or bar, and PT or NPT thread variants to order. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.

GC30015MC2G AirTAC F.R.L. Combination, G1/2, Manual Drain Technical Specifications

ModelGC30015MC2G AirTAC F.R.L. Combination, G1/2, Manual Drain
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30015MC2G AirTAC F.R.L. Combination, G1/2, Manual Drain

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the GC30015MC2G AirTAC F.R.L. Combination, G1/2, Manual Drain Is Used

factory

Automotive assembly-line air supply

Feeds a clean, regulated and lubricated air supply to impact wrenches, nutrunners and clamping fixtures along a vehicle assembly line, with the psi gauge letting line technicians verify set pressure at a glance and the manual drain cleared during shift checks.

conveyor_belt

Packaging and case-sealing machinery

Prepares air for carton sealers, palletisers and conveyor diverters in a distribution centre, filtering out water and particles, holding a steady regulator setting for consistent cylinder stroking, and metering oil mist to extend actuator life.

engineering

Machine-shop CNC and pneumatic fixtures

Serves a CNC cell with pneumatic clamps, tool-change cylinders and air blow-off, giving the shop a single point of filtration, pressure regulation and lubrication at the cell drop, with the manual drain emptied as part of daily machine start-up.

Is the GC30015MC2G AirTAC F.R.L. Combination, G1/2, Manual Drain the Right Station?

Start with the port and size step: this unit is size 300 with 1/2 in ports, so match it to the air line and the flow your machines actually draw - larger sizes carry larger ports and more flow, and we can confirm the flow curves against your demand before you order. Choose the drain type for the filter bowl: manual (as here) suits attended installations, while automatic or differential-pressure drain suits points that are not checked daily. The standard element is 40 um; specify the 5 um option (code W) where downstream valves and cylinders need finer filtration. Gauges can be ordered with MPa, psi or bar scales, and the thread can be PT (standard), G or NPT as an order option. Because flow is published as curves and not a single rating, send us your application details and we will confirm sizing from the datasheet.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

GC30015MC2G AirTAC F.R.L. Combination, G1/2, Manual Drain FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a rated flow number. Tell us your line pressure and the air demand of the equipment you want to feed, and we will confirm the sizing from the datasheet on request.

The M in GC30015MC2G specifies a manual drain on the filter bowl: collected water is drained by hand during routine checks, which suits installations that are visited daily. If the unit will sit unattended, the GC family can be ordered with an automatic or differential-pressure drain instead - just ask when ordering.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30015MC2G AirTAC F.R.L. Combination, G1/2, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015MC2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.