verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30015MF2WGK AirTAC F.R.L. Combination, G1/2

The AirTAC GC30015MF2WGK AirTAC F.R.L. Combination, G1/2 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$98.08 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30015MF2WGK AirTAC F.R.L. Combination, G1/2

The GC30015MF2WGK is a three-piece AirTAC GC series F.R.L. combination: a filter, a pressure regulator and a lubricator assembled as one air-preparation station. This configuration is built around a G1/2 (BSPP) port on the 300 size body. The filter element is the fine 5 um grade (the W option, versus the standard 40 um), and the filter bowl uses a manual drain, so an operator opens the drain valve to release collected water. The regulator is the standard type with an adjustment range of 0.05-0.9 MPa (7-130 psi) and carries an embedded square gauge scaled in psi; an external round gauge is available as an option. A reverse/check valve is fitted, and the mounting bracket is included. Bowls on the 300 size are polycarbonate (PC).

This is a genuine AirTAC part. The GC series spans sizes 200, 300, 400 and 600, with port sizes from 1/8 in up to 1 in, drain choices (differential-pressure, automatic or manual), 40 um or 5 um filtration, gauge scale options in MPa, psi or bar, and PT, G or NPT threads. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.

GC30015MF2WGK AirTAC F.R.L. Combination, G1/2 Technical Specifications

ModelGC30015MF2WGK AirTAC F.R.L. Combination, G1/2
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30015MF2WGK AirTAC F.R.L. Combination, G1/2

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 5 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the GC30015MF2WGK AirTAC F.R.L. Combination, G1/2 Is Used

precision_manufacturing

CNC machining centre air supply

Feeds clean, regulated and lubricated air to a CNC machining centre's pneumatic clamps and tool-change cylinders, with the 5 um element protecting fine valve internals and the psi gauge letting setters read set pressure directly.

conveyor_belt

Packaging and bottling conveyor line

Conditions the air feeding conveyor stops, diverters and case-packing cylinders on a packaging line, where the check valve holds downstream pressure if the upstream supply dips and the manual drain is emptied during shift checks.

factory

Automotive assembly pneumatic tool station

Serves a drop point on an automotive assembly line powering impact wrenches and air cylinders, delivering filtered, pressure-regulated, oil-mist-lubricated air from one bracket-mounted station at the workstation.

Is the GC30015MF2WGK AirTAC F.R.L. Combination, G1/2 the Right Station?

Start with the port step: the 300 size carries the 1/2 in port here, and moving up or down a size (200/300/400/600) changes both the port and the flow capacity, so match the size to the air demand of the circuit. Because flow is published as curves and not a single rating, send us your application's air consumption and we will confirm sizing against the datasheet before you order. Then settle the real decode choices: drain type (manual here, with automatic and differential-pressure available), filter grade (5 um as coded, versus the 40 um standard), gauge scale (psi here; MPa and bar also offered), thread (PT is the standard; G and NPT are catalogue options to order), and bracket or no-bracket variants. If your line already has filtration or regulation, a GFC two-unit or a single GF/GR/GL unit may fit better than this three-unit set.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

GC30015MF2WGK AirTAC F.R.L. Combination, G1/2 FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a figure here. Send us your application's air demand and working pressure and we will confirm the flow from the datasheet and check that the 300 size at 1/2 in is the right step before you order.

The M in the code specifies a manual drain on the filter bowl: an operator opens the drain to release collected water, which suits stations that are checked regularly. AirTAC also offers automatic drains (code A) and differential-pressure drains (the default, no code) on the GC series, and the regulator adjustment range depends on the drain type: 0.05-0.9 MPa (7-130 psi) with a manual drain, 0.15-0.9 MPa (20-130 psi) with automatic or differential-pressure drains. This unit, with its manual drain, uses the wider 0.05-0.9 MPa range.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30015MF2WGK AirTAC F.R.L. Combination, G1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015MF2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.