verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30015MLC2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure

The AirTAC GC30015MLC2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$87.35 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30015MLC2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure

The GC30015MLC2 is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one treatment stack. This configuration is size 300 with PT1/2 ports, a 40 um standard filter element, a manual-drain bowl, a low-pressure type regulator, and a round pressure gauge with a psi scale. The polycarbonate bowls on the filter and lubricator suit general indoor compressed-air duty, the mounting bracket is included, and the manual drain is emptied by hand as part of routine maintenance.

This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600 with a choice of port sizes, PT (standard), G or NPT threads, differential-pressure, automatic or manual drains, 40 um or 5 um (W) filtration, gauge styles and scales, and low-pressure or standard regulator types. Rated flow for this series is published as curves rather than a single figure, so ask us and we will confirm the datasheet figures for your application on request.

GC30015MLC2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure Technical Specifications

ModelGC30015MLC2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30015MLC2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the GC30015MLC2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure Is Used

factory

Packaging-line air supply

Feeding clean, regulated and lubricated air to the pneumatic cylinders and actuators on a carton-forming and sealing line, with the manual drain emptied during scheduled changeovers.

conveyor_belt

Conveyor drive and gate cylinders

Conditioning the air supply to conveyor gate and diverter cylinders on a distribution line, where the low-pressure regulator setting and psi gauge suit the plant's standard operating pressure.

build

Workshop air drops

A wall-mounted treatment point at a maintenance workshop air drop, filtering water and particles from the ring main, holding a set pressure, and oil-misting the tools connected downstream.

Is the GC30015MLC2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure the Right Station?

Start with the port size: this unit is size 300 with PT1/2 ports; step up to size 400 or 600 if the line needs a larger connection, or down to 200 for smaller ports. Choose the drain to match maintenance habits: manual (as here) is emptied by hand, automatic drains continuously, and the differential-pressure default drains on a pressure drop. Filtration is 40 um standard; specify the W option for 5 um where finer particle removal matters. The regulator here is the low-pressure type; the standard type covers the usual 0.05-0.9 MPa range, and we will confirm the low-pressure adjustment range on request. Gauge scale is psi on this unit (MPa or bar are alternatives), and the thread is PT as standard with G and NPT available to order. Because flow for this series is published as curves and not a single rating, send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

GC30015MLC2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure FAQ

AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote a number here. Tell us your line pressure and the air demand of your equipment, and we will confirm the sizing from the datasheet on request.

The M in the code selects a manual-drain bowl, which is emptied by hand during routine checks - a good fit where the unit is easily accessible and maintenance is scheduled. If you prefer, the same size 300 combination can be ordered with an automatic drain or the differential-pressure default drain instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30015MLC2 AirTAC F.R.L. Combination, PT1/2, Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015MLC2 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.