verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

GC30015MLC2G AirTAC F.R.L. Combination, G1/2, Low-Pressure

The AirTAC GC30015MLC2G AirTAC F.R.L. Combination, G1/2, Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$86.85 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC300-15 drain, gauge and thread option on one page All GC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC30015MLC2G AirTAC F.R.L. Combination, G1/2, Low-Pressure

The GC30015MLC2G is a genuine AirTAC three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one GC300 unit. It cleans compressed air of water and particulate down to the standard 40 um grade, regulates downstream pressure, and adds lubricating oil mist for air-powered tools and actuators. This configuration is built around a G1/2 (BSPP) port on the size-300 body, uses a manual drain on the filter bowl, and is the low-pressure regulator type. A round gauge with a psi scale is fitted so operators can read and set the regulated pressure directly, and the mounting bracket is included for solid panel or frame installation.

This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600 with port sizes stepping from 1/8 in up to 1 in, and with choices of drain type, filter grade (40 um standard, 5 um optional), gauge style and scale, thread form (PT standard; G and NPT as order options) and reverse/check valve. Flow is published by AirTAC as curves rather than a single rated figure, so we confirm the datasheet and flow figures for your application on request.

GC30015MLC2G AirTAC F.R.L. Combination, G1/2, Low-Pressure Technical Specifications

ModelGC30015MLC2G AirTAC F.R.L. Combination, G1/2, Low-Pressure
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC30015MLC2G AirTAC F.R.L. Combination, G1/2, Low-Pressure

GC300G-series F.R.L. combination, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-15 filter, GR300-15 regulator and GL300-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/2" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-15
Build orderFilter → regulator → lubricator

Where the GC30015MLC2G AirTAC F.R.L. Combination, G1/2, Low-Pressure Is Used

factory

Automotive paint-shop air drops

Feeding spray guns and air-assisted applicators on a paint line, where the filter strips water and pipe scale, the lubricator mists oil to the gun's air motor, and the low-pressure regulator holds a gentle, repeatable supply pressure at the booth.

precision_manufacturing

CNC machining-centre air supply

Conditioning the shop-air feed into a CNC cell: clean, dry-ish air to the tool changer and clamps, regulated pressure read locally on the psi gauge, and oil mist carried to air cylinders and pneumatic fixtures downstream.

settings_input_component

Packaging-machine FRL feed

Mounted on the bracket at the air inlet of a cartoning or wrapping machine, giving the machine's valve manifold filtered, lubricated air at a set pressure, with the manual drain emptied during scheduled changeover and maintenance rounds.

Is the GC30015MLC2G AirTAC F.R.L. Combination, G1/2, Low-Pressure the Right Station?

Start with the port step: this unit is size 300 with a G1/2 port, one of the mid sizes in the 200/300/400/600 range - step up or down a size if your line's port standard or demanded air volume differs, and ask us to confirm sizing against the published flow curves before ordering. The manual drain here means an operator or maintenance round opens the drain to expel collected water, which suits stations that are already visited regularly; an automatic or differential-pressure drain variant removes that task if the unit will sit unattended. The 40 um grade is the standard element for general plant air; specify the W code if you need the 5 um element. The fitted round gauge reads in psi; square embedded gauges and MPa or bar scales are the alternative. Thread is G (BSPP) on this unit - PT is the catalogue standard and NPT is orderable, so match your piping. The bracket is included. The regulator is the low-pressure type; its exact adjustment range is not published in our sheet, so confirm it with us if your setpoint is near the bottom or top of a standard range.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-15 regulator with a GF300-15 filter on that branch.

GC30015MLC2G AirTAC F.R.L. Combination, G1/2, Low-Pressure FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a rated flow, Cv or l/min figure for this unit. Tell us your line pressure and the air demand of the equipment it will feed, and we will confirm the sizing against the datasheet curves on request before you order.

The M in the code selects a manual drain on the filter bowl: collected water is expelled by opening the drain during maintenance rounds, unlike the automatic or differential-pressure drain options that discharge on their own. The L code makes this the low-pressure regulator variant, intended for lower setpoints than the standard type; its exact adjustment range is not published in our sheet, so confirm it with us if your setpoint is critical.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC30015MLC2G AirTAC F.R.L. Combination, G1/2, Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC30015MLC2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.