verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC400-10 AirTAC F.R.L. Combination G3/8 5 um Manual Drain

The AirTAC GC400-10 AirTAC F.R.L. Combination G3/8 5 um Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$136.59 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-10 drain, gauge and thread option on one page All GC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400-10 AirTAC F.R.L. Combination G3/8 5 um Manual Drain

The GC400-10 is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one set for compressed-air preparation. This configuration is built for 3/8 in (G3/8) lines at size 400. The filter element is the fine 5 um grade (the standard element is 40 um; W codes the 5 um option) with a manual drain on the bowl, which is polycarbonate at this size. The regulator is the low-pressure type and carries a fitted external round gauge with a psi scale, and a reverse/check valve is fitted on the regulator. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC series spans sizes 200, 300, 400 and 600 with matching port sizes, and options include drain type (differential-pressure, automatic or manual), filter grade (40 um standard, 5 um optional), gauge style and scale (MPa, psi or bar), thread (PT standard; G and NPT are order options) and bracket. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.

GC400-10 AirTAC F.R.L. Combination G3/8 5 um Manual Drain Technical Specifications

ModelGC400-10 AirTAC F.R.L. Combination G3/8 5 um Manual Drain
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400-10 AirTAC F.R.L. Combination G3/8 5 um Manual Drain

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the GC400-10 AirTAC F.R.L. Combination G3/8 5 um Manual Drain Is Used

factory

Automotive assembly plant air drops

Feeding impact tools, nutrunners and air cylinders at assembly stations that need filtered, regulated and lubricated air on a 3/8 in branch line, with the 5 um element protecting tight-tolerance tools.

conveyor_belt

Food and beverage packaging line

Supplying carton sealers, case packers and conveyor actuation cylinders where fine filtration, a set working pressure and consistent oil mist keep actuators running shift after shift.

precision_manufacturing

CNC machine shop pneumatic circuits

Preparing air for clamping fixtures, tool-change cylinders and chip-clearing jets on machining centres, where the check valve holds the downstream circuit if supply pressure dips.

Is the GC400-10 AirTAC F.R.L. Combination G3/8 5 um Manual Drain the Right Station?

Start with the port step: size 400 on a 3/8 in line suits mid-size drops; step up or down (200/300/400/600) according to the flow your line needs, since larger sizes carry larger ports and more flow. Choose the drain to match the installation: manual drain (this unit) needs an operator to bleed the bowl, while automatic and differential-pressure drains handle it without attention. Choose the 5 um element (this unit, code W) where downstream valves and cylinders need finer air than the standard 40 um element. This is the low-pressure regulator type, so confirm the working band of your application with us before ordering. Gauge style and scale are selectable (embedded square gauge standard; external round gauge fitted here, psi scale). Thread is PT as standard with G and NPT as order options, and a mounting bracket is included.

Be aware that flow is published as curves, not a single rated number, so we cannot quote one figure here. Send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

GC400-10 AirTAC F.R.L. Combination G3/8 5 um Manual Drain FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Tell us your line pressure and the air demand of your equipment, and we will confirm the sizing against the datasheet on request before you order.

The M in the code specifies a manual drain, so an operator opens the drain to remove accumulated water from the filter bowl. AirTAC also offers automatic and differential-pressure drains in the same sizes; if unattended draining suits your installation better, ask us for the equivalent GC400 variant.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400-10 AirTAC F.R.L. Combination G3/8 5 um Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40010MLC2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.