verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC400-15LC2K AirTAC F.R.L. Combination, PT1/2, Low-Pressure

The AirTAC GC400-15LC2K AirTAC F.R.L. Combination, PT1/2, Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$136.84 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC400-15LC2K AirTAC F.R.L. Combination, PT1/2, Low-Pressure

The GC400-15LC2K is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one 400-size set with a 1/2 in PT port. The filter section removes water and particulate down to 40 um (the standard grade), the differential-pressure drain bleeds collected condensate automatically as flow varies, and the lubricator meters oil mist into the downstream air. The regulator is the low-pressure type, and this configuration carries a round external gauge scaled in psi plus a reverse/check valve fitted. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GC line is offered in 200/300/400/600 sizes with port options from 1/8 in to 1 in, PT as the standard thread and G (BSPP) or NPT as order options, a choice of differential-pressure, automatic or manual drains, 40 um or 5 um (W) filtration, and gauge or no-gauge variants. The 400-size bowls are polycarbonate; only size 600 uses aluminium alloy. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.

GC400-15LC2K AirTAC F.R.L. Combination, PT1/2, Low-Pressure Technical Specifications

ModelGC400-15LC2K AirTAC F.R.L. Combination, PT1/2, Low-Pressure
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC400-15LC2K AirTAC F.R.L. Combination, PT1/2, Low-Pressure

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the GC400-15LC2K AirTAC F.R.L. Combination, PT1/2, Low-Pressure Is Used

precision_manufacturing

Automotive paint and finishing line

Feeds spray guns and air-assisted applicators on a finishing line: filtered, regulated and lubricated air in one set keeps atomising air clean and consistently conditioned across a shift.

conveyor_belt

Packaging and case-sealing machinery

Supplies the cylinders and air grippers on carton formers, case packers and sealing heads, where the low-pressure regulator band and oil-mist lubrication suit long-running actuator duty.

factory

General plant air drop for assembly benches

Installed at the point of use on a workshop air drop serving impact drivers, clamps and small presses, combining water and 40 um particulate removal with regulation and lubrication in one 1/2 in unit.

Is the GC400-15LC2K AirTAC F.R.L. Combination, PT1/2, Low-Pressure the Right Station?

Step up or down through the 200/300/400/600 sizes to match the port and the flow your line needs - the 400 size with its 1/2 in PT port suits mid-to-large circuits. Choose the drain: differential-pressure (as fitted here) drains with flow, automatic (code A) drains on a timer-free cycle, manual (code M) needs an operator. Filter grade is 40 um standard; specify W for 5 um where finer particulate control matters. This unit is the low-pressure regulator type, so confirm your working band suits it before ordering. Gauge choices are embedded square (standard) or external round, with MPa, psi or bar scales - this configuration has a round psi gauge. Thread is PT as standard; G (BSPP) and NPT are order options. A mounting bracket is included. Flow is published as curves, not a single rating, so send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

GC400-15LC2K AirTAC F.R.L. Combination, PT1/2, Low-Pressure FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a rated flow number. Send us your application details and we will confirm the relevant flow-curve and datasheet figures for this 400-size, 1/2 in unit on request before you order.

The L in the code marks the low-pressure regulator type, intended for working bands below the standard regulator range; the exact adjustment range for this type is not published in our sheet, so confirm your working pressure with us before ordering. C2 in the code means an external round gauge scaled in psi is fitted; the embedded square gauge is the standard option, with MPa, psi or bar scales available.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC400-15LC2K AirTAC F.R.L. Combination, PT1/2, Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015LC2K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.