verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC40010ALC2WGK AirTAC F.R.L. Combination, G3/8

The AirTAC GC40010ALC2WGK AirTAC F.R.L. Combination, G3/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$146.82 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-10 drain, gauge and thread option on one page All GC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC40010ALC2WGK AirTAC F.R.L. Combination, G3/8

The AirTAC GC40010ALC2WGK is a three-piece F.R.L. combination: a filter, a pressure regulator and a lubricator assembled as one air-treatment set for compressed air. This size 400 configuration is specified with G3/8 ports, a 5 um filter element (the finer of the two catalogue grades), an automatic drain on the filter bowl, a low-pressure regulator type, a round pressure gauge reading in psi, a reverse/check valve, and a mounting bracket. It conditions air in one pass: water and particulate are drained off, downstream pressure is set on the regulator, and oil mist is metered to lubricate downstream air tools and actuators.

This is a genuine AirTAC part. The GC family is published in sizes 200, 300, 400 and 600, with port options, drain types, filter grades, gauge styles and scales to suit the application. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and flow figures for your application on request.

GC40010ALC2WGK AirTAC F.R.L. Combination, G3/8 Technical Specifications

ModelGC40010ALC2WGK AirTAC F.R.L. Combination, G3/8
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC40010ALC2WGK AirTAC F.R.L. Combination, G3/8

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the GC40010ALC2WGK AirTAC F.R.L. Combination, G3/8 Is Used

precision_manufacturing

CNC machining cell air clamps

Feeds filtered, regulated and lubricated air to the clamp cylinders and tool-change actuators on a machining centre, with the 5 um element protecting close-tolerance valve spools and the psi gauge letting setters verify clamp pressure at the cell.

factory

Bottling line wrap and seal stations

Supplies treated air to the grippers, wrap arms and sealing cylinders on a bottling or packaging line, where the automatic drain keeps condensate out of the circuit during washdown-heavy shifts and the lubricator oils the cylinders in continuous duty.

air

Automotive body shop pneumatic hand tools

Mounted at the drop for impact wrenches, ratchets and air screwdrivers in a body or assembly shop, metering oil mist to the tools, holding a stable set pressure via the regulator, and using the check valve to keep the circuit from dumping on supply loss.

Is the GC40010ALC2WGK AirTAC F.R.L. Combination, G3/8 the Right Station?

Size 400 with G3/8 ports sits in the middle of the GC range; step up to size 600 or down to 300/200 if your line's flow demand points elsewhere - we can check the published flow curves against your consumption before you order. The 5 um element (code W) suits applications that need finer particulate removal than the 40 um standard; the automatic drain empties the bowl without manual attention, which matters where the unit is mounted in a hard-to-reach spot. The gauge here is the external round type reading in psi; embedded square gauges and MPa or bar scales are the other catalogue choices. Thread is specified as G (BSPP) on this unit - PT is the standard thread and G/NPT are order options. A bracket is included, and the reverse/check valve holds downstream settings if upstream supply is interrupted.

Note that this is the low-pressure regulator type; the exact adjustment range for the low-pressure variant is not published in the sheet we work from, so confirm your set pressure with us before ordering. Flow is published as curves, not a single rating - ask us to confirm sizing against the application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

GC40010ALC2WGK AirTAC F.R.L. Combination, G3/8 FAQ

AirTAC publishes flow for this family as curves, not as a single rated figure, so we do not quote a l/min, m3/h or SCFM number. Send us your application's flow demand and line pressure and we will confirm the figures from the datasheet on request before you order.

The code decodes it that way: A is the automatic drain (instead of the differential-pressure default or a manual drain), and W is the 5 um filter grade instead of the 40 um standard. The automatic drain removes condensate without operator attention, and the 5 um element gives finer particulate removal. If you would rather have the 40 um element or a different drain type, that is a catalogue option - just tell us which configuration you need.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC40010ALC2WGK AirTAC F.R.L. Combination, G3/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40010ALC2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.