verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC40010C2W AirTAC F.R.L. Combination, PT3/8, 5 um

The AirTAC GC40010C2W AirTAC F.R.L. Combination, PT3/8, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$125.46 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-10 drain, gauge and thread option on one page All GC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC40010C2W AirTAC F.R.L. Combination, PT3/8, 5 um

The GC40010C2W is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one set. This size 400 unit carries a PT3/8 (3/8 in) port with standard PT thread, a 5 um filter element (the finer of the two catalogue grades), differential-pressure drain, and a round gauge with psi scale. It filters water and particulate from compressed air, holds a set downstream pressure, and meters oil mist into the air line for tools and actuators that need lubrication.

This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, drain choices, 40 um or 5 um filtration, and gauge options. Flow is published as curves rather than a single rating, so we confirm the datasheet figures for your application on request.

GC40010C2W AirTAC F.R.L. Combination, PT3/8, 5 um Technical Specifications

ModelGC40010C2W AirTAC F.R.L. Combination, PT3/8, 5 um
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC40010C2W AirTAC F.R.L. Combination, PT3/8, 5 um

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the GC40010C2W AirTAC F.R.L. Combination, PT3/8, 5 um Is Used

precision_manufacturing

CNC machine tool air supply

Feeds filtered, regulated and lubricated air to a machining centre's pneumatic tool-changer and clamping circuits, with 5 um filtration protecting fine-control valves.

conveyor_belt

Packaging line cylinder supply

Conditions the air feeding conveyor stopper and carton-forming cylinders on a packaging line, keeping moisture and grit out while oil mist lubricates the cylinders.

factory

Assembly plant air drops

Installed as a point-of-use F.R.L. at an assembly-plant work cell, giving operators clean, regulated, lubricated air for air tools and small actuators.

Is the GC40010C2W AirTAC F.R.L. Combination, PT3/8, 5 um the Right Station?

Size 400 with a PT3/8 port sits in the middle of the GC range; step up to size 600 or down to 300/200 depending on the flow your line needs. The 5 um element (code W) suits applications more sensitive to particulate than the 40 um standard grade. The differential-pressure drain bleeds accumulated water automatically as flow passes the unit, with no timer or operator action. The round psi gauge is fitted here; embedded square gauges and MPa or bar scales are the other catalogue choices. PT thread is standard on this code, with G (BSPP) and NPT available to order as specifications. A mounting bracket is included.

Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your air consumption before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

GC40010C2W AirTAC F.R.L. Combination, PT3/8, 5 um FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a figure here. Tell us your line pressure and air consumption and we will confirm the sizing from the datasheet on request.

The W in the code GC40010C2W selects the 5 um element, the finer of the two catalogue grades, where downstream valves and cylinders need cleaner air than the 40 um standard provides. The differential-pressure drain still removes collected water automatically.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC40010C2W AirTAC F.R.L. Combination, PT3/8, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40010C2W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.