verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC40010LC2WGK AirTAC F.R.L. 3-Unit, G3/8, 5 um

The AirTAC GC40010LC2WGK AirTAC F.R.L. 3-Unit, G3/8, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$136.46 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-10 drain, gauge and thread option on one page All GC400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC40010LC2WGK AirTAC F.R.L. 3-Unit, G3/8, 5 um

The GC series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator supplied together as one conditioning set. This GC40010LC2WGK is the 400 size with G3/8 ports in G (BSPP) thread. The filter stage carries the 5 um element (code W) with a differential-pressure drain, the regulator is the low-pressure type fitted with an external round gauge scaled in psi, and a reverse/check valve (K) is fitted. Bowls are polycarbonate at this size, and the mounting bracket is included.

This is a genuine AirTAC part. The GC family spans 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, a choice of differential-pressure, automatic or manual drains, 40 um or 5 um filtration, gauge style and scale, PT, G or NPT threads, and standard or low-pressure regulators. Max inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm figures from the datasheet for your application.

GC40010LC2WGK AirTAC F.R.L. 3-Unit, G3/8, 5 um Technical Specifications

ModelGC40010LC2WGK AirTAC F.R.L. 3-Unit, G3/8, 5 um
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC40010LC2WGK AirTAC F.R.L. 3-Unit, G3/8, 5 um

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the GC40010LC2WGK AirTAC F.R.L. 3-Unit, G3/8, 5 um Is Used

conveyor_belt

Bottling-line gripper cylinders

Conditioned air for the gripper and pusher cylinders on a bottling conveyor: 5 um filtration protects seals from grit and water, the low-pressure regulator suits sensitive actuation, and the lubricator feeds a steady oil mist to keep cylinders and valves running smoothly.

build

Assembly-cell impact tools

Feeds impact wrenches and nut runners at an assembly bench. The lubricator delivers a continuous oil mist for the air motors, the 5 um element keeps abrasive particles out of the tools, and the round psi gauge lets operators set and check line pressure at a glance.

precision_manufacturing

Weld-cell clamp fixtures

Supplies filtered, regulated and lubricated air to pneumatic clamps and swing cylinders in a robotic weld cell. The reverse/check valve protects the downstream circuit if supply is interrupted, and the differential-pressure drain handles condensate without a manual drain valve.

Is the GC40010LC2WGK AirTAC F.R.L. 3-Unit, G3/8, 5 um the Right Station?

Size and port step up with flow demand: 200, 300, 400 and 600 map to larger ports, and this unit sits at 400 with G3/8 in G thread (PT is the standard thread; G and NPT are order options). The drain is differential-pressure here, with automatic (A) and manual (M) available; filtration is 5 um (W) against the 40 um standard. The gauge is the external round type scaled in psi; an embedded square gauge is standard, with MPa, psi or bar scales. The regulator is the low-pressure type (L) with a reverse/check valve (K) fitted, and the mounting bracket is included. Because flow is published as curves rather than a single rated figure, send us your application details and we will confirm sizing from the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

GC40010LC2WGK AirTAC F.R.L. 3-Unit, G3/8, 5 um FAQ

AirTAC publishes GC-series flow as performance curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and other datasheet figures for the GC40010LC2WGK on request.

The L in GC40010LC2WGK marks the low-pressure regulator type. Its exact adjustment range is not published in the catalogue data we work from, so we confirm it on request rather than quoting a figure. If your line needs the standard adjustment range instead, the same 400 size is available without the L code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC40010LC2WGK AirTAC F.R.L. 3-Unit, G3/8, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40010LC2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.