verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC40010LF2G AirTAC F.R.L. Unit, Low-Pressure, G3/8

The AirTAC GC40010LF2G AirTAC F.R.L. Unit, Low-Pressure, G3/8 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$125.10 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC40010LF2G AirTAC F.R.L. Unit, Low-Pressure, G3/8

The GC40010LF2G is an AirTAC GC-series three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one unit. This configuration is the 400 size with a G3/8 (3/8 in) G-thread port, a 40 um standard filter element, a differential-pressure drain on the filter bowl, and a low-pressure type regulator. A square pressure gauge with a psi scale is fitted, the polycarbonate bowls suit the 400 size, the mounting bracket is included, and no reverse/check valve is fitted. It treats compressed air in one pass: water and particulate are drained off, downstream pressure is set on the regulator, and a fine oil mist is carried into the air line to lubricate downstream pneumatic components.

This is a genuine AirTAC part. The GC family is published in 200, 300, 400 and 600 sizes with port sizes from 1/8 in to 1 in, and options across thread type (PT standard, G and NPT to order), drain type, filter grade (40 um standard, 5 um with code W), gauge style and scale, and reverse/check valve. Flow figures for this series are published as curves rather than a single rated number, so ask us and we will confirm the datasheet figures for your application on request.

GC40010LF2G AirTAC F.R.L. Unit, Low-Pressure, G3/8 Technical Specifications

ModelGC40010LF2G AirTAC F.R.L. Unit, Low-Pressure, G3/8
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC40010LF2G AirTAC F.R.L. Unit, Low-Pressure, G3/8

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the GC40010LF2G AirTAC F.R.L. Unit, Low-Pressure, G3/8 Is Used

factory

Paint and coating line make-up air

Feeds filtered, regulated and lubricated air to spray-booth actuation and mask-lifting cylinders on a finishing line, where the low-pressure regulator type suits circuits set well below full line pressure and the lubricator keeps air cylinders running smoothly shift after shift.

conveyor_belt

Packaging and case-packing line supply

Serves as the single air-preparation point for a carton erector and case packer: the 40 um element strips water and debris before the valves, the regulator holds a steady setting for the sealing cylinders, and the oil mist lubricates the diverters and pushers.

precision_manufacturing

CNC machining cell clamping circuit

Prepares the air feeding power clamps and tool-change actuators on a machining cell, with the square psi gauge giving the operator a visible setpoint, the differential-pressure drain clearing condensate as the element loads, and the lubricator conditioning the clamp cylinders.

Is the GC40010LF2G AirTAC F.R.L. Unit, Low-Pressure, G3/8 the Right Station?

Start with the port step: the 400 size carries a 3/8 in port, and the GC range steps through 200, 300, 400 and 600 as port size and flow capacity rise - match the size to the air demand of the line rather than the pipe alone. For the drain, the differential-pressure type on this unit discharges condensate automatically whenever the pressure drop across the element is high enough; a fully automatic (A) or manual (M) drain can be ordered instead if your duty or access suits it better. The 40 um element is the standard grade; specify W for the 5 um element where finer filtration is needed. The fitted square gauge reads in psi; external round gauges and MPa or bar scales are alternatives. Thread is G here, with PT as the catalogue standard and NPT orderable. Note the L code: this is the low-pressure regulator type, so its adjustment range differs from the standard type - confirm the exact range with us before ordering. Finally, flow for this series is published as curves, not a single rating, so send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

GC40010LF2G AirTAC F.R.L. Unit, Low-Pressure, G3/8 FAQ

AirTAC publishes flow for the GC series as characteristic curves rather than a single rated figure, so we do not quote a rated flow number for this unit. Send us your application details - the machines or cylinders served, working pressure and duty - and we will confirm the datasheet flow figures against your requirement on request before you order.

L marks the low-pressure type of regulator in this combination, rather than the standard type. It is chosen for circuits that operate at lower set pressures. The exact adjustment range for the low-pressure type is not published in the catalogue sheet we work from, so please confirm the range with us on request. The rest of the code decodes as: 400 size, 3/8 in port, G thread, square gauge with psi scale, differential-pressure drain and 40 um filtration.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC40010LF2G AirTAC F.R.L. Unit, Low-Pressure, G3/8

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40010LF2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.