verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC40015ALC2G AirTAC F.R.L. Combination G1/2 Low-Pressure

The AirTAC GC40015ALC2G AirTAC F.R.L. Combination G1/2 Low-Pressure is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$135.35 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC40015ALC2G AirTAC F.R.L. Combination G1/2 Low-Pressure

The GC40015ALC2G is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one complete air-treatment set. This size 400 configuration is built with G1/2 (BSPP) ports, a 40 um filter element, and an automatic drain on the filter bowl, so collected condensate is expelled without manual attention. The regulator is the low-pressure type and carries a round external gauge reading in psi, and the unit ships with a mounting bracket fitted. The polycarbonate bowls suit the standard working range, with a maximum inlet pressure of 1.0 MPa (145 psi) and an operating temperature of -5 to 70 C (non-freezing).

This is a genuine AirTAC part from the GC combination family, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8" to 1". Across the range you can specify thread options (PT standard, G or NPT to order), drain types, filter grades and gauge scales. Because AirTAC publishes flow for these units as curves rather than a single rated figure, we confirm the datasheet and flow figures for your application on request.

GC40015ALC2G AirTAC F.R.L. Combination G1/2 Low-Pressure Technical Specifications

ModelGC40015ALC2G AirTAC F.R.L. Combination G1/2 Low-Pressure
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC40015ALC2G AirTAC F.R.L. Combination G1/2 Low-Pressure

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the GC40015ALC2G AirTAC F.R.L. Combination G1/2 Low-Pressure Is Used

precision_manufacturing

Pneumatic press and clamping station feed

Installed at the drop feeding a pneumatic press or clamp station, the set removes water and chips from the supply air, holds a steady low-pressure setting at the ram, and mists oil into the air feeding the cylinders and valves.

factory

Assembly-line air tool manifold

Mounted on the manifold serving an assembly line's impact wrenches, nutrunners and air ratchets, the combination cleans the shop air, regulates the tool supply pressure and keeps the tool motors lubricated through the shift.

settings_input_component

Packaging machinery air preparation

Fitted in the air-preparation cabinet of packaging and case-sealing machinery, the unit conditions the supply for the machine's valves and actuators, with the automatic drain handling condensate and the psi gauge giving operators a visible line-pressure check.

Is the GC40015ALC2G AirTAC F.R.L. Combination G1/2 Low-Pressure the Right Station?

Start with size and port: the GC series steps through sizes 200 / 300 / 400 / 600, and the 400 size here carries 1/2" ports - step up or down according to the flow your line needs, and ask us to confirm the flow curve against your demand before ordering. The filter element is the 40 um standard grade; a 5 um element is available as the W option if finer particulate removal is required. The automatic drain on this model suits unattended installations; manual and differential-pressure drains are the other catalogue choices. The regulator in this code is the low-pressure type, so confirm the control band suits your circuit - the standard-type GC units carry the published 0.15-0.9 MPa (20-130 psi) auto-drain range. The round gauge here reads in psi; embedded square gauges and MPa or bar scales are the alternatives. Thread is G (BSPP) on this code - PT is the standard thread and NPT is also an order option - and a mounting bracket is included.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

GC40015ALC2G AirTAC F.R.L. Combination G1/2 Low-Pressure FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote one number here. Tell us your line pressure and the flow your application needs, and we will confirm the sizing against the datasheet curves on request before you order.

The L in the code GC40015ALC2G marks the low-pressure regulator variant, intended for circuits where the working pressure sits below the standard type's normal band; the exact range for this variant is not published, so confirm it with us against your setpoint. The A in the code is the automatic drain: the filter bowl expels collected condensate on its own, so no manual draining is needed in normal service.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC40015ALC2G AirTAC F.R.L. Combination G1/2 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015ALC2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.