verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC40015C2GK AirTAC F.R.L. Combination Unit, G1/2 Port

The AirTAC GC40015C2GK AirTAC F.R.L. Combination Unit, G1/2 Port is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$136.19 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC40015C2GK AirTAC F.R.L. Combination Unit, G1/2 Port

The AirTAC GC40015C2GK is a three-piece F.R.L. combination that cleans, regulates and lubricates compressed air at the point of use. The filter section removes water and particulate down to 40 um through a differential-pressure drain, the regulator holds downstream pressure anywhere in its 0.15-0.9 MPa (20-130 psi) adjustment range, and the lubricator feeds an oil mist to downstream tools. This unit is built around a G1/2 port, is rated to 1.0 MPa (145 psi) maximum inlet pressure, and operates from -5 to 70 C in non-freezing conditions. It is supplied with a round psi-scale gauge, a reverse/check valve fitted on the regulator, and a mounting bracket.

This is a genuine AirTAC part from the GC series, which spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch and options including automatic or manual drains, a 5 um filter element (code W), gauge scales in MPa, psi or bar, and PT, G or NPT threads. Flow figures are published as curves rather than a single rating, so ask us to confirm the datasheet numbers for your application.

GC40015C2GK AirTAC F.R.L. Combination Unit, G1/2 Port Technical Specifications

ModelGC40015C2GK AirTAC F.R.L. Combination Unit, G1/2 Port
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC40015C2GK AirTAC F.R.L. Combination Unit, G1/2 Port

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the GC40015C2GK AirTAC F.R.L. Combination Unit, G1/2 Port Is Used

factory

Automotive paint shop air supply

Feeds filtered, pressure-regulated and lubricated air to spray booths and air-driven paint equipment on a finishing line, where clean, dry, correctly lubricated air protects finish quality and gun life.

precision_manufacturing

CNC machining centre air prep

Sits at the air inlet of a CNC machine tool or machining cell, conditioning the supply that actuates tool changers, clamps and pneumatic axes at a stable set pressure.

conveyor_belt

Packaging line actuator supply

Conditions the air feeding cylinders and vacuum generators on a cartoning or palletising conveyor line, keeping seals and moving parts lubricated while holding line pressure steady.

Is the GC40015C2GK AirTAC F.R.L. Combination Unit, G1/2 Port the Right Station?

Choose the GC size by the port and flow your line needs: this 400 size carries a 1/2 inch port, one step up from 3/8 and one down from 3/4. Drain type is a real choice - differential-pressure (as here, the default), automatic for unattended condensate removal, or manual where you bleed the bowl by hand. Filter grade is 40 um standard; specify the W code for 5 um when downstream equipment needs finer filtration. Gauge scale is selectable (MPa, psi or bar) and this unit carries the external round gauge in psi. Thread is PT as standard, with G and NPT available as order options - this unit is the G-thread version. A reverse/check valve (code K) holds the regulator setting if upstream pressure is lost.

Because flow is published only as curves and not as a single rated figure, ask us to confirm sizing against your air consumption before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

GC40015C2GK AirTAC F.R.L. Combination Unit, G1/2 Port FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote one number. Tell us your line pressure and air consumption and we will confirm the correct sizing from the datasheet on request.

The K code in GC40015C2GK means a reverse/check valve is fitted, which holds the regulator setting if upstream pressure drops. The drain is the differential-pressure type (the default) and the filter element is the standard 40 um grade; automatic or manual drains and a 5 um element are available as order options.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC40015C2GK AirTAC F.R.L. Combination Unit, G1/2 Port

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015C2GK and will confirm price, stock and lead time — usually within 7-8 hours.