verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC40015LC2G AirTAC F.R.L. Combination Unit, G1/2

The AirTAC GC40015LC2G AirTAC F.R.L. Combination Unit, G1/2 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$124.99 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC40015LC2G AirTAC F.R.L. Combination Unit, G1/2

The GC40015LC2G is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one supply unit. This configuration is built around a G1/2 (BSPP) port in the size-400 frame, with a 40 um filter element, a differential-pressure drain on the filter bowl, and a low-pressure type regulator for lines that run below standard working pressures. The fitted external round gauge reads in psi, the filter and regulator bowls are polycarbonate at this size, and the mounting bracket is included.

This is a genuine AirTAC part. The GC family spans sizes 200, 300, 400 and 600, with port options from 1/8 in to 1 in, automatic, manual or differential-pressure drains, a 5 um filter element as an option, gauge scales in MPa, psi or bar, and PT, G or NPT threads. Rated flow for this combination is published as curves rather than a single figure, so ask us and we will confirm the datasheet figures against your application.

GC40015LC2G AirTAC F.R.L. Combination Unit, G1/2 Technical Specifications

ModelGC40015LC2G AirTAC F.R.L. Combination Unit, G1/2
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC40015LC2G AirTAC F.R.L. Combination Unit, G1/2

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the GC40015LC2G AirTAC F.R.L. Combination Unit, G1/2 Is Used

factory

Centralized plant air supply

Installed at the point where the compressor ring feeds a production hall, the GC40015LC2G filters water and particulate from the main line, holds a steady low working pressure for downstream tools, and carries oil mist to keep actuators lubricated.

precision_manufacturing

Pneumatic press and clamping fixtures

On a machining cell with air-operated clamps and a pneumatic press, this combination conditions the supply in one unit: clean air for the valves, a stable regulated pressure for consistent clamping force, and lubrication for the cylinder seals.

conveyor_belt

Packaging and conveyor lines

Feeding the cylinders and air jets on a packaging or conveyor line, the unit removes line moisture before it reaches the diverters, regulates pressure for gentle product handling, and mists oil into the supply to extend actuator life.

Is the GC40015LC2G AirTAC F.R.L. Combination Unit, G1/2 the Right Station?

Size and port set the capacity envelope: the 400 size with its 1/2 in G-thread port suits mid-to-large supply lines, but the right step depends on the flow your circuit actually draws, so size up or down against the published curves. Drain choice matters on the filter: differential-pressure (as coded here) drains only when the pressure drop calls for it, automatic drains continuously, and manual relies on an operator. The 40 um element is the standard grade; specify the W code for 5 um where finer particulate removal is needed. Gauge scale is selectable (MPa, psi or bar - this unit is psi), and the low-pressure type regulator is the correct pick when your working pressure sits below the standard regulator band. Thread is G (BSPP) on this code; PT is the catalogue standard with G and NPT as order options. Flow is published as curves, not a single rating - ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

GC40015LC2G AirTAC F.R.L. Combination Unit, G1/2 FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote one number. Tell us your line pressure and the flow your circuit needs, and we will confirm the datasheet curve figures for this exact configuration before you order.

The L code in GC40015LC2G means the regulator is the low-pressure type, intended for circuits that run below the standard regulator band. The exact adjustment range for the low-pressure type is not published in the standard table, so ask us to confirm it against your working pressure. If your line runs at conventional pressures, the standard type (no L code) is the usual choice.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC40015LC2G AirTAC F.R.L. Combination Unit, G1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015LC2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.