AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC40015LC2WK AirTAC F.R.L. Combination, PT1/2

The AirTAC GC40015LC2WK AirTAC F.R.L. Combination, PT1/2 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$136.85 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC40015LC2WK AirTAC F.R.L. Combination, PT1/2

The GC40015LC2WK is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one complete air-treatment set. This 400-size configuration is ported PT1/2, carries the 5 um filter element (code W) instead of the standard 40 um, and uses a differential-pressure drain on the filter bowl. The regulator is the low-pressure type, and this unit is fitted with a round external pressure gauge on a psi scale plus a reverse/check valve (code K). All bowls on this size are PC (polycarbonate), and the mounting bracket is included.

This is a genuine AirTAC part. The GC family is offered in sizes 200, 300, 400 and 600, with port sizes from 1/8 in to 1 in, PT as the standard thread and G (BSPP) or NPT as order options, a choice of differential-pressure, automatic or manual drain, 40 um or 5 um filtration, gauge scale in MPa, psi or bar, and an optional reverse/check valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application on request.

GC40015LC2WK AirTAC F.R.L. Combination, PT1/2 Technical Specifications

ModelGC40015LC2WK AirTAC F.R.L. Combination, PT1/2
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC40015LC2WK AirTAC F.R.L. Combination, PT1/2

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the GC40015LC2WK AirTAC F.R.L. Combination, PT1/2 Is Used

precision_manufacturing

CNC machining centre air supply

Feeds clean, regulated and lubricated air to a machining centre's clamping fixtures, tool-change cylinders and pneumatic gates from a 1/2 in shop-air drop, with the 5 um element protecting fine pilot valves.

factory

Automotive paint shop air drops

Conditions the air feeding spray guns and air-assisted equipment on a paint line, where the 5 um grade and oil-mist lubrication support consistent gun operation at the booth.

conveyor_belt

Packaging and bottling line actuators

Supplies the cylinders and air-driven diverters on a packaging or bottling conveyor, with the regulator holding a stable low-pressure setting and the check valve holding downstream pressure if the supply dips.

Is the GC40015LC2WK AirTAC F.R.L. Combination, PT1/2 the Right Station?

Start with the port step: this unit is the 400 size at PT1/2, one step above the 300 series, so step up or down according to the air demand of the circuit - flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering. This configuration already fixes several choices: 5 um filtration (the W element, one grade finer than the 40 um standard), a differential-pressure drain, the low-pressure regulator type, a round gauge on a psi scale, and a fitted reverse/check valve. If you would rather have the standard 40 um element, an automatic or manual drain, a square embedded gauge, or an MPa or bar scale, those are available in the same family. Thread is PT as standard; G (BSPP) and NPT versions are order options, and the mounting bracket is included with this unit.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

GC40015LC2WK AirTAC F.R.L. Combination, PT1/2 FAQ

AirTAC publishes flow for this family as performance curves rather than a single rated figure, so we do not quote one number. Tell us your application and we will confirm the flow and sizing from the datasheet on request before you order.

L marks the low-pressure regulator type, and K means a reverse/check valve is fitted, so downstream pressure is held if the supply line loses pressure. The code also shows C2 (round gauge, psi scale) and W (5 um filter element instead of the 40 um standard); the drain is the differential-pressure type, the standard default.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC40015LC2WK AirTAC F.R.L. Combination, PT1/2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015LC2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.