verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC40015MC2K AirTAC F.R.L. Combination, PT1/2, 40 um

The AirTAC GC40015MC2K AirTAC F.R.L. Combination, PT1/2, 40 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$136.81 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC40015MC2K AirTAC F.R.L. Combination, PT1/2, 40 um

The AirTAC GC40015MC2K is a three-piece F.R.L. combination that filters, regulates and lubricates compressed air in one assembled set: a separate filter, a separate regulator and a separate oil-mist lubricator. This configuration is built on the GC400 size with PT1/2 ports, 40 um standard filtration, a manual drain on the filter bowl, a fitted round gauge reading in psi, and a reverse/check valve on the regulator to hold downstream pressure when the upstream supply is lost. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). The filter and lubricator bowls on this 400 size are polycarbonate (PC).

This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600, with port options, thread options (PT standard; G and NPT are order options), drain types (differential-pressure, automatic or manual), a 5 um filter grade (code W), gauge scale choices and bracket options. Because flow is published as curves rather than a single rated figure, we confirm the datasheet and flow figures for your application on request.

GC40015MC2K AirTAC F.R.L. Combination, PT1/2, 40 um Technical Specifications

ModelGC40015MC2K AirTAC F.R.L. Combination, PT1/2, 40 um
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC40015MC2K AirTAC F.R.L. Combination, PT1/2, 40 um

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the GC40015MC2K AirTAC F.R.L. Combination, PT1/2, 40 um Is Used

factory

Automotive assembly line air drops

Feeding impact wrenches, nut runners and pneumatic presses at assembly stations, where the filter removes water and swarf, the regulator sets tool pressure and the lubricator mists oil to extend tool life.

conveyor_belt

Packaging and bottling line cylinders

Supplying the air circuits that drive carton-forming cylinders, clamp actuators and diverters on a packaging conveyor, with the check valve holding the set pressure if the shop supply dips.

engineering

Machine shop clamping fixtures

Preparing air for pneumatic clamps and swing cylinders on CNC fixtures, where stable regulated pressure protects the workpiece and the oil mist keeps sealing surfaces moving smoothly.

Is the GC40015MC2K AirTAC F.R.L. Combination, PT1/2, 40 um the Right Station?

Start with the size and port: the GC400 with PT1/2 sits in the middle of the 200/300/400/600 range, so step up or down depending on the air demand of the machines downstream - we can confirm sizing against the published flow curves before you order. Choose the drain type for the filter bowl: manual drain (this unit, code M) suits attended installations where an operator drains the bowl; automatic or differential-pressure drains suit unattended lines. Filter grade is 40 um standard on this unit; specify 5 um (code W) where finer particulate removal is needed. The fitted round gauge reads in psi; square embedded gauges and MPa/psi/bar scales are the other gauge choices. Thread is PT as standard, with G (BSPP) and NPT available as order options, and a mounting bracket is included.

One honest note on sizing: AirTAC publishes flow for this family as curves, not as a single rated number, so please ask us to confirm the flow figure against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

GC40015MC2K AirTAC F.R.L. Combination, PT1/2, 40 um FAQ

AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a rated flow number. Tell us your application and we will confirm the flow and datasheet figures for this unit on request before you order.

The M in the code means the filter bowl has a manual drain: an operator opens it to release collected water, which suits attended installations. If your line runs unattended, order the GC40015 with an automatic (A) or differential-pressure (blank) drain instead - the rest of the decode stays the same.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC40015MC2K AirTAC F.R.L. Combination, PT1/2, 40 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015MC2K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.