verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC40015MC2WK AirTAC F.R.L. Combination, PT1/2, 5 um

The AirTAC GC40015MC2WK AirTAC F.R.L. Combination, PT1/2, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$136.83 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC40015MC2WK AirTAC F.R.L. Combination, PT1/2, 5 um

The GC40015MC2WK is a three-piece AirTAC F.R.L. combination: a filter, a pressure regulator and an oil-mist lubricator, each in its own body and joined as one air-preparation set for 1/2 in (PT1/2) pipework. This configuration carries a 5 um filter element (code W) with a manual drain on the filter bowl, a standard regulator adjustable from 0.05 to 0.9 MPa (7-130 psi), a fitted round pressure gauge reading in psi, a reverse/check valve on the regulator, and a mounting bracket. The polycarbonate bowls suit non-freezing compressed air from -5 to 70 C, with a maximum inlet pressure of 1.0 MPa (145 psi).

This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600, with port options from 1/8 to 1 in, PT (standard), G or NPT threads, automatic, manual or differential-pressure drains, 40 um or 5 um filtration, and gauge scales in MPa, psi or bar. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.

GC40015MC2WK AirTAC F.R.L. Combination, PT1/2, 5 um Technical Specifications

ModelGC40015MC2WK AirTAC F.R.L. Combination, PT1/2, 5 um
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC40015MC2WK AirTAC F.R.L. Combination, PT1/2, 5 um

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the GC40015MC2WK AirTAC F.R.L. Combination, PT1/2, 5 um Is Used

factory

Automotive assembly line air drops

Feeding impact wrenches, nutrunners and air ratchets at assembly stations, where the 5 um element protects tools from fine particulate, the regulator holds a steady working pressure and the lubricator mists oil into the tool air supply.

conveyor_belt

Packaging and cartoning machine supply

Preparing air for conveyor diverters, case erectors and packaging cylinders on a production line, with the reverse/check valve helping hold the downstream pressure setting and the manual drain bled during scheduled line cleaning.

handyman

Machine shop pneumatic workbench

A point-of-use set at a maintenance bench or jig station, supplying spray guns, air clamps and small cylinders from a shop compressor, with the psi round gauge giving a direct local reading of the set pressure.

Is the GC40015MC2WK AirTAC F.R.L. Combination, PT1/2, 5 um the Right Station?

Start with the port size: this 400-size unit is supplied with PT1/2 connections, and the GC series steps through sizes 200 to 600 as port and flow capacity rise. Choose the drain to match maintenance access: this unit has a manual drain, which needs periodic bleeding by hand; automatic and differential-pressure drains are available on other codes. Filtration here is the finer 5 um element (code W) instead of the 40 um standard, which suits downstream equipment that is sensitive to finer particulate. The fitted round gauge reads in psi; MPa and bar scales are offered on other codes. Thread is PT as standard, with G (BSPP) and NPT as order options, and the mounting bracket is included.

Because flow for the GC series is published as curves and not as a single rated number, send us your application details and we will confirm the sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

GC40015MC2WK AirTAC F.R.L. Combination, PT1/2, 5 um FAQ

AirTAC publishes flow for the GC series as performance curves rather than a single rated figure, so we do not quote a l/min or SCFM number. Send us your application details and we will confirm the datasheet flow curves and sizing for this 400-size, PT1/2 unit before you order.

The M in the code selects a manual drain on the filter bowl: collected water and contaminant are released by hand, so the bowl needs periodic bleeding as part of routine maintenance. If you prefer unattended drainage, GC codes with automatic or differential-pressure drains are available in the same size range.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC40015MC2WK AirTAC F.R.L. Combination, PT1/2, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015MC2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.