AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC40015MLF2GK AirTAC F.R.L. Combination, G1/2, Manual Drain

The AirTAC GC40015MLF2GK AirTAC F.R.L. Combination, G1/2, Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$136.47 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC40015MLF2GK AirTAC F.R.L. Combination, G1/2, Manual Drain

The GC40015MLF2GK is a three-piece AirTAC GC-series F.R.L. combination that filters, regulates and lubricates compressed air in one assembled set: a separate filter, regulator and lubricator. This configuration is built in the 400 size with 1/2 in ports threaded G (BSPP). The filter element is the standard 40 um grade for water and particulate removal, with a manual drain on the PC (polycarbonate) bowl, so an operator drains accumulated condensate by hand. The regulator is the low-pressure type, and this unit carries an embedded square gauge scaled in psi. A reverse/check valve is fitted, and a mounting bracket is included.

This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600, with port sizes from 1/8 in to 1 in, PT as the standard thread and G or NPT as order options, a choice of differential-pressure, automatic or manual drains, 40 um or 5 um (W) filtration, and gauge scales in MPa, psi or bar. Flow is published as curves rather than a single rated figure, so we confirm the datasheet and flow figures for your application on request.

GC40015MLF2GK AirTAC F.R.L. Combination, G1/2, Manual Drain Technical Specifications

ModelGC40015MLF2GK AirTAC F.R.L. Combination, G1/2, Manual Drain
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC40015MLF2GK AirTAC F.R.L. Combination, G1/2, Manual Drain

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 40 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the GC40015MLF2GK AirTAC F.R.L. Combination, G1/2, Manual Drain Is Used

factory

Automotive paint shop air drops

Feeds filtered, regulated and lubricated air to spray-booth and paint-line drops in an automotive plant, where clean, moisture-reduced air protects finish quality and the lubricator keeps air tools running smoothly.

conveyor_belt

Packaging line actuator supply

Conditions the supply to pneumatic cylinders and grippers on a carton-forming and wrapping conveyor line, with the 1/2 in ports serving the main drop feeding multiple stations.

precision_manufacturing

CNC machine shop tool circuits

Sits at the machine inlet of a CNC machining cell, filtering water and swarf-carrying particulate out of the shop air, holding a set pressure to the tool-change circuit and oil-mist lubricating the air motors.

Is the GC40015MLF2GK AirTAC F.R.L. Combination, G1/2, Manual Drain the Right Station?

Start with the size and port: the 400 size with 1/2 in ports sits in the middle of the GC range (200/300/400/600), and the right step depends on the air demand of the downstream circuit - move up a size if your flow requirement is near the top of a smaller unit's curve. Choose the drain to suit access: manual drain (this unit) suits attended installations, while automatic or differential-pressure drains suit unattended ones. Choose 40 um for general protection or the 5 um (W) element where finer filtration is needed. Pick the gauge scale - this unit is square, psi - and confirm the thread: PT is the standard, with G and NPT as order options (this unit is G).

One honest note before ordering: flow is published as curves, not a single rated number, so ask us to confirm sizing against your application and the datasheet before you commit. The low-pressure regulator's exact adjustment range is likewise confirmed on request.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

GC40015MLF2GK AirTAC F.R.L. Combination, G1/2, Manual Drain FAQ

AirTAC publishes flow for this family as curves, not as a single rated figure, so we do not quote a rated flow number. Tell us your application and required air demand and we will confirm the flow figures from the datasheet on request before you order.

The M in the code sets a manual drain: an operator opens the drain on the polycarbonate filter bowl by hand to remove collected condensate, which suits installations that are checked regularly. The L sets the low-pressure regulator type; its exact adjustment range is not published in the catalogue data we hold, so we confirm it on request. Everything else decodes as: 400 size, 1/2 in G-threaded ports, 40 um standard filter element, embedded square gauge scaled in psi, a fitted reverse/check valve, and an included mounting bracket.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC40015MLF2GK AirTAC F.R.L. Combination, G1/2, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015MLF2GK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.