The AirTAC GC40015MLF2W AirTAC F.R.L. 1/2 in, 5 um, Manual Drain is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$125.64 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC40015MLF2W AirTAC F.R.L. 1/2 in, 5 um, Manual Drain

The AirTAC GC40015MLF2W is a three-piece F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one GC400 unit. This configuration is the 400 size with a PT1/2 port, a manual-drain filter bowl fitted with the finer 5 um element (code W), a low-pressure type regulator, and an embedded square gauge reading in psi. The polycarbonate bowls let you see condensate and oil level at a glance, and the mounting bracket is included.

This is a genuine AirTAC part. The GC series is offered in sizes 200, 300, 400 and 600, with ports from 1/8 in to 1 in, PT as the standard thread and G or NPT as order options, plus choices of drain type, filter grade, gauge scale and bracket. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rating, so ask us to confirm figures from the datasheet for your application.

GC40015MLF2W AirTAC F.R.L. 1/2 in, 5 um, Manual Drain Technical Specifications

ModelGC40015MLF2W AirTAC F.R.L. 1/2 in, 5 um, Manual Drain
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC40015MLF2W AirTAC F.R.L. 1/2 in, 5 um, Manual Drain

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the GC40015MLF2W AirTAC F.R.L. 1/2 in, 5 um, Manual Drain Is Used

conveyor_belt

Packaging line multi-cylinder supply

Feeds filtered, regulated and lubricated air to the clamp, pusher and seal cylinders on a carton-forming packaging machine, with the 5 um element protecting the directional valves from particulate and the lubricator keeping the cylinder seals working smoothly.

factory

Automotive assembly cell actuation

Mounted at the drop of a robotic welding cell, the unit conditions the air feeding grippers and clamps: water and 5 um filtration for the valves, low-pressure regulation matched to the cell's working pressure, and oil mist for the air tools used at the same station.

precision_manufacturing

CNC machine pneumatic clamping

Supplies conditioned air to the pneumatic clamps and tool-change cylinders on a CNC machining centre, where the square psi gauge gives the operator a direct pressure readout, the manual drain is emptied during shift checks, and the bracket fixes the set beside the machine's air inlet.

Is the GC40015MLF2W AirTAC F.R.L. 1/2 in, 5 um, Manual Drain the Right Station?

Start with the size and port: the 400 size steps up to a 1/2 in PT port, and larger sizes carry more flow, so match the step to the air demand of the circuit. Because flow is published as curves and not a single rated figure, ask us to confirm sizing against your application before ordering. From there the real choices are: drain type (manual here; automatic and differential-pressure are available), filter grade (5 um as on this unit, or the 40 um standard), gauge scale (psi on this unit; MPa and bar scales exist), and thread (PT standard, G or NPT to order). Note this unit is the low-pressure regulator type, so choose it for circuits that run at lower working pressures. A bracket is included. If you only need filtration plus regulation, a GFR filter-regulator covers it; the GC three-unit set adds the lubricator for a complete F.R.L.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

GC40015MLF2W AirTAC F.R.L. 1/2 in, 5 um, Manual Drain FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated number, so we do not quote a l/min or SCFM figure. Send us your application details and we will confirm the flow figures from the datasheet and check the 400 size against your demand before you order.

The manual drain means an operator opens the bowl drain during routine checks instead of relying on automatic or differential-pressure action - a good fit where the unit is inspected regularly. The 5 um element (code W) is the finer option over the 40 um standard, chosen when downstream valves and cylinders need cleaner air. Both choices are decodable from the model code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC40015MLF2W AirTAC F.R.L. 1/2 in, 5 um, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015MLF2W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.