verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

GC40015MLF2WGK AirTAC F.R.L. Combination G1/2, 5 um

The AirTAC GC40015MLF2WGK AirTAC F.R.L. Combination G1/2, 5 um is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$136.49 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC40015MLF2WGK AirTAC F.R.L. Combination G1/2, 5 um

The GC40015MLF2WGK is an AirTAC GC-series three-unit F.R.L. combination: a separate filter, regulator and lubricator assembled as one supply package for compressed air. This configuration is built around a G1/2 (BSPP) port on the size 400 body. The filter element is the fine 5 um grade (code W) and the bowl uses a manual drain, so an operator opens the drain valve periodically to remove collected water instead of relying on an automatic or differential-pressure drain. The regulator is the low-pressure type, fitted with an embedded square gauge reading in psi for direct setpoint checks, and a reverse/check valve is fitted to hold downstream conditions if supply pressure is lost. A mounting bracket is included.

This is a genuine AirTAC part. The GC three-unit F.R.L. family is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and can be ordered with manual, automatic or differential-pressure drains, 40 um or 5 um filtration, square or round gauges with MPa, psi or bar scales, PT, G or NPT threads, and with or without a reverse/check valve. Flow is published as curves rather than a single rating, so ask us to confirm the flow and datasheet figures for your application before ordering.

GC40015MLF2WGK AirTAC F.R.L. Combination G1/2, 5 um Technical Specifications

ModelGC40015MLF2WGK AirTAC F.R.L. Combination G1/2, 5 um
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC40015MLF2WGK AirTAC F.R.L. Combination G1/2, 5 um

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the GC40015MLF2WGK AirTAC F.R.L. Combination G1/2, 5 um Is Used

precision_manufacturing

CNC machining centre air supply

Feeds filtered, regulated and lubricated air to the tool-change clamps, air bearings and actuated doors of a CNC machining centre, with the 5 um element protecting fine pilot valves from particulate carryover.

conveyor_belt

Packaging line actuation

Supplies the carton-forming cylinders, sealing heads and divertor gates on a packaging conveyor line, giving operators one point to set line pressure, top up oil mist and drain the bowl during shift checks.

air

Spray booth atomising air

Conditions the air feeding spray guns in a paint or coating booth, where the 5 um grade limits water and particle spotting on the finish and the lubricator mists oil for the gun's air motor.

Is the GC40015MLF2WGK AirTAC F.R.L. Combination G1/2, 5 um the Right Station?

Start with the port and size step: this unit is size 400 with a G1/2 port; smaller or larger sizes (200/300/400/600) step port and flow capacity up or down, so match the step to the air demand of the machine it feeds. Because flow is published as curves and not as a single rated figure, ask us to confirm sizing against your application before ordering. Next choose the drain: this code carries a manual drain, which suits attended installations; automatic or differential-pressure drains are available on other codes for unattended duty. Filtration here is the 5 um fine grade (code W); the 40 um standard grade is the alternative where only coarse water and particulate removal is needed. The gauge on this unit is the embedded square type with a psi scale; MPa or bar scales and an external round gauge are options. Thread is G (BSPP) on this code; PT is the standard thread and G/NPT are order options. A mounting bracket is included.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

GC40015MLF2WGK AirTAC F.R.L. Combination G1/2, 5 um FAQ

AirTAC publishes flow for this family as curves rather than a single rated figure, so we do not quote a number that is not in the datasheet. Send us your line pressure and air demand and we will confirm the flow figures from the datasheet for this exact unit on request.

The L marks the low-pressure type of regulator, suited to applications where the setpoint sits below the standard range; the exact range for this variant is not published, so confirm it with us on request. The M marks a manual drain on the filter bowl, meaning an operator opens the drain valve periodically to expel collected water - automatic (A) and differential-pressure (blank) drains are available on other codes for unattended duty.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC40015MLF2WGK AirTAC F.R.L. Combination G1/2, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC40015MLF2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.