verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC600 · F.R.L. Combination (filter + regulator + lubricator)

GC600-25MLC2 AirTAC F.R.L. 1 in PT Low-Pressure Unit

The AirTAC GC600-25MLC2 AirTAC F.R.L. 1 in PT Low-Pressure Unit is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1" ports, a 40 µm element, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$188.02 Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC600-25 drain, gauge and thread option on one page All GC600-25 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GC600-25MLC2 AirTAC F.R.L. 1 in PT Low-Pressure Unit

The GC600-25MLC2 is an AirTAC GC-series three-unit F.R.L. combination: a separate air filter, pressure regulator and oil-mist lubricator assembled as one supply package. This configuration is the 600 size with a 1 in PT port, a 40 um filter element, a manual bowl drain, the low-pressure regulator type, and a round pressure gauge reading in psi. The filter bowls on this size are aluminium alloy, and a mounting bracket is included.

This is a genuine AirTAC part. The GC family is available in sizes 200, 300, 400 and 600 with a choice of PT, G or NPT thread, differential-pressure, automatic or manual draining, a 40 um standard or 5 um (W) filter element, and gauge or no-gauge variants. Flow figures are published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.

GC600-25MLC2 AirTAC F.R.L. 1 in PT Low-Pressure Unit Technical Specifications

ModelGC600-25MLC2 AirTAC F.R.L. 1 in PT Low-Pressure Unit
SeriesGC600 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1" (PT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialAluminium alloy
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GC600-25MLC2 AirTAC F.R.L. 1 in PT Low-Pressure Unit

GC600G-series F.R.L. combination, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-25 filter, GR600-25 regulator and GL600-25 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC600 · PT1" · 40 µm
One size downGC400
Two-unit equivalentGFC600-25
Build orderFilter → regulator → lubricator

Where the GC600-25MLC2 AirTAC F.R.L. 1 in PT Low-Pressure Unit Is Used

factory

Automotive assembly line air drops

Feeds a filtered, regulated and lubricated air drop serving impact wrenches and pneumatic clamps along a vehicle assembly line, with the manual drain emptied during scheduled shift checks.

conveyor_belt

Bottling and packaging conveyor actuators

Conditions the supply to pneumatic cylinders and diverters on a bottling conveyor, removing water and particulate, holding a stable low set pressure and carrying oil mist to the actuators.

engineering

Heavy fabrication plant tool circuits

Prepares plant air for large-bore tool circuits in a steel fabrication shop, where the 1 in PT port matches the main drop and the round psi gauge lets operators verify set pressure at a glance.

Is the GC600-25MLC2 AirTAC F.R.L. 1 in PT Low-Pressure Unit the Right Station?

Start with the port step: this unit is the 600 size with a 1 in PT connection, the largest in the GC range, so step down to 200/300/400 if your line diameter and air demand are smaller. Choose the drain to match access: manual draining (as coded here) needs someone to open the bowl, while automatic (A) and differential-pressure (default) drain without attention. Pick the filter grade: 40 um standard, 5 um with the W code for finer protection. Gauge styles are embedded square or external round, with MPa, psi or bar scales; this code carries a round psi gauge. Thread is PT as standard, with G (BSPP) and NPT as order options, and a bracket is included.

One honest note on sizing: AirTAC publishes flow as curves, not a single rated figure, so send us your air demand and we will confirm the correct size against the datasheet before you order. This unit is the low-pressure regulator type; its exact adjustment range is not published in the catalogue and we will confirm it on request.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-25 regulator with a GF600-25 filter on that branch.

GC600-25MLC2 AirTAC F.R.L. 1 in PT Low-Pressure Unit FAQ

AirTAC publishes flow for this family as curves, not as a single rated number, so we do not quote a l/min or SCFM figure. Send us your air demand and line conditions and we will confirm the sizing from the datasheet on request.

The M in the code selects a manual bowl drain: someone opens it to release collected water, which suits attended installations with scheduled checks. The same 600 size is available with automatic (A) draining or the differential-pressure drain as the default, and the 40 um element can be swapped for the finer 5 um W grade.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GC600-25MLC2 AirTAC F.R.L. 1 in PT Low-Pressure Unit

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC60025MLC2 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.