The AirTAC GC60020ALC2G AirTAC F.R.L. Combination Unit, G3/4 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/4" ports, a 40 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC60020ALC2G is an AirTAC GC series three-piece F.R.L. combination unit: a separate air filter, pressure regulator and oil-mist lubricator assembled as one supply package. This configuration is the 600 size with a G3/4 port, a 40 um filter element with automatic drain, a low-pressure type regulator, and a round pressure gauge reading in psi. The filter bowls on this 600 size are aluminium alloy, and a mounting bracket is included.
This is a genuine AirTAC part. The GC series is available in sizes 200, 300, 400 and 600 with a choice of ports, thread types (PT standard; G and NPT as order options), drain types, filter grades (40 um standard, 5 um optional), gauge styles and scales. Flow figures are published as curves rather than a single rating, so ask us to confirm the datasheet for your application before ordering.
| Model | GC60020ALC2G AirTAC F.R.L. Combination Unit, G3/4 |
|---|---|
| Series | GC600 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT3/4" (G (BSPP) thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC600 | G-series F.R.L. combination, 600 body — sets the port range. |
|---|---|
| 20 | Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF600-20 filter, GR600-20 regulator and GL600-20 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC600 · PT3/4" · 40 µm |
|---|---|
| One size down | GC400 |
| Two-unit equivalent | GFC600-20 |
| Build order | Filter → regulator → lubricator |
Installed at a large distribution point on a factory compressed-air ring main, this three-piece unit filters water and particulate from the supply, holds the downstream pressure setpoint and meters oil mist to the tools and actuators fed from that drop.
On a packaging line running cylinders, grippers and vacuum-assist valves, the GC60020ALC2G conditions the branch feed: the 40 um element removes water and debris, the regulator sets the working pressure for the machine section, and the lubricator carries oil mist to the air-operated components.
Fitted ahead of a machining cell's pneumatic panel, this unit gives the cell one conditioning point: clean, regulated, lubricated air for clamps, tool-change cylinders and air blow-off circuits, with the psi gauge giving operators a local pressure reference.
The GC series lets you step size and port to the job: this unit is the 600 size at G3/4, the largest step in the range, so match it against the air demand of the line rather than the pipe size alone. The automatic drain on the filter bowl discharges collected condensate without manual attention, which suits unmanned or high-duty installations; manual and differential-pressure drain variants exist if you prefer different service behaviour. The 40 um element is the standard grade for general plant air; a 5 um element (code W) is available when finer filtration is needed. The round gauge here reads in psi; square gauges and MPa or bar scales are the other catalogue choices. Thread is G (BSPP) on this code, with PT standard and NPT available to order. Flow is published as curves, not a single rated figure, so send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The aluminium-alloy bowls on the GC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR600-20 regulator with a GF600-20 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote one number on the page. Tell us your application and we will confirm the flow figures from the datasheet on request, so you can size the unit against your actual air demand before ordering.
The L in the model code marks this as the low-pressure type of regulator, intended for applications where the downstream setpoint sits below the standard type's range; the exact adjustment range for the low-pressure type is not published on our sheet, so confirm it with us on request. The A in the code is the drain: the filter bowl drains collected condensate automatically, so the line does not depend on someone opening a manual drain.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.